Hypervisor IX Monitoring System
System, Network And Communication, Physiological Monitors. 510(k) K150632, from Shenzhen Mindray Bio-Medical Electronics Co., Ltd. (Shenzhen, CN). Product code MSX, class 2.
As of Nov 17, 2026, K150632 is an FDA 510(k) held by Shenzhen Mindray Bio-Medical Electronics Co., Ltd., substantially equivalent on Jul 6, 2015 after 117 days, with 2 recalls tied to it in FDA's recall database.
- Substantially equivalent: Jul 6, 2015
- Review time: 117 days
- Recalls: 2
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe indications for use of the Hypervisor IX Monitoring System include: • Real time viewing of patient clinical data and alarms • Storage and Historical review of patient clinical data and alarms • Printing of real time and historical patient data • Configuration of local settings as well as synchronizing settings across the network to a remote device • Transfer of patient clinical data and…
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Hypervisor Central Monitoring System (Including Telemetry Monitoring System, TMS-6016)K132036 · Shenzhen Mindray Bio-Meidcal Electronics Co., Ltd. · Jul 1, 2014
- St/Ar St And Arrhythmia Software Model: Release K.OK101521 · Philips Medical Systems · Jul 29, 2010
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- BeneVision Central Monitoring SystemK162607 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Apr 20, 2017
- Passport Series Patient Monitors (including Passport 17m, Passport 12m and T1)K152902 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Feb 18, 2016
Recalls
Recalls FDA ties to K150632, newest first; each opens FDA's recall record| Jul 14, 2017 | Z-0554-2018A damaged circuit board in the battery charger can cause the battery to overcharge and the battery case to swell and separate. | Terminated |
| Sep 8, 2016 | Z-0321-2017Mindray has become aware that the TD60 Display Telemetry Transmitter used with the BeneVision Central Station may crack on the bezel surrounding the display and also the transmitter may not power on or will power on but… | Terminated |
Other MSX Clearances
The newest 510(k)s for the same product code; their median review was 266 days; see every MSX device- eClinicsK260075 · Ceiba Healthcare US, Inc. · Oct 7, 2026
- Digistat CareK261287 · Ascom Ums Srl Unipersonale · Sep 12, 2026
- Dashboard (P007000)K260211 · Hill-Rom, Inc. · Aug 13, 2026
- Corsano CardioWatch 287-2 SystemK261367 · Corsano Health B.V. · Jul 26, 2026
- IntelliVue Measurement Rack 6000 (867317)K253654 · Philips Medizin Systeme Böblingen GmbH · Mar 30, 2026
- TigerConnect Alarm ManagementK243270 · Tigerconnect · Sep 30, 2025
- BeneVision Central Monitoring SystemK242728 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Jul 31, 2025
- Central StationK242750 · Nihon Kohden Digital Health Solutions, LLC · Jun 5, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 11, 2015
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files