DR Systems Zero Download 3D Viewer (Z3D)
System, Image Processing, Radiological. 510(k) K143318, from Dr Systems, Inc. (San Diego, CA). Product code LLZ, class 2.
As of Nov 19, 2026, K143318 is an FDA 510(k) held by Dr Systems, Inc., substantially equivalent on Mar 10, 2015 after 111 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 111 days
- Recalls: 2
- Cited as a predicate by: 1 device
DR Systems Z3D is intended to provide reading physicians, referring physicians, and other appropriate healthcare professionals tools to aid in interpreting medical images, including: • Displaying DICOM compliant medical image volumes, such as CT, MRI, and PET.
- Voxar 3D Enterprise, Model 6.1K060505 · Barcoview Mis Edinburgh · Mar 29, 2006
- IBM iConnect AccessK182290 · Merge Healthcare Incorporated · Sep 25, 2018
| Aug 14, 2017 | Z-3105-2017The software is not identifying the patient as having atypical hyperplasia, resulting in an incorrect Gail Risk calculation. | Terminated |
| Aug 7, 2017 | Z-2566-2018The software is not identifying the patient as having atypical hyperplasia, resulting in an incorrect Gail Risk calculation. | Terminated |
- 3D Anatomical ModelK262132 · The Jacobs Institute · Nov 5, 2026
- LiLi DICOM Viewer (LiLi )K260454 · Elevate Imaging, Inc. · Nov 4, 2026
- Vitrea Advanced Visualization, Version 7.16K263648 · Canon Medical Informatics, Inc. · Oct 29, 2026
- MIM – KineticIDK261763 · Mim Software, Inc. · Oct 26, 2026
- PV-iCurve ProK261531 · Perception Vision Medical Technology Co., Ltd. · Oct 21, 2026
- Eden PACSK261788 · Higia., Inc. d/b/a Eden · Oct 21, 2026
- Syngo Carbon Space (VA4)K263048 · Siemens Healthineers AG · Sep 29, 2026
- Syneris PACS v.1.0.1.0K261874 · Syneris · Sep 23, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 19, 2014
- Review panel
- Radiology
- Regulation
- 21 CFR 892.2050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files