Klassic BiPolar System
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented. 510(k) K143113, from Total Joint Orthopedics (Salt Lake City, UT). Product code KWY, class 2.
As of Nov 17, 2026, K143113 is an FDA 510(k) held by Total Joint Orthopedics, substantially equivalent on Jan 28, 2015 after 90 days, with 1 recall tied to it in FDA's recall database.
- Substantially equivalent: Jan 28, 2015
- Review time: 90 days
- Recalls: 1
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Biopro Polar HeadK100761 · Biopro, Inc. · Dec 3, 2010
- Nihon Kohden Bedside Monitor, Bsm 9100A SeriesK082785 · Nihon Kohden America, Inc. · Nov 26, 2008
- Klassic Hd Hip SystemK100445 · Total Joint Orthopedics, Inc. · Dec 3, 2010
- Spectron Conversion Endoprosthesis CupK823726 · Richard'S Medical Equip., Inc. · Mar 9, 1983
Recalls
Recalls FDA ties to K143113, newest first; each opens FDA's recall record| Started | Reason | Status |
|---|---|---|
| Sep 23, 2025 | Z-0432-2026Potential packaging issue that could compromise the sterile barrier. Defect may result in loss of sterility of the device, presenting potential risk of infection if device is implanted. | Open, Classified |
Other KWY Clearances
The newest 510(k)s for the same product code; their median review was 195 days; see every KWY device- b-ONE® Bipolar HeadK253357 · B-One Ortho, Corp. · Apr 13, 2026
- Maxx Libertas Bipolar Hip Head (Bipolar Hip)K243634 · Maxx Orthopedics, Inc. · Aug 25, 2025
- CORAIL Cemented Femoral StemK231526 · Depuy Ireland UC · Dec 19, 2023
- SpaceFlex Acetabular CupK223441 · G21, S.R.L. · Mar 23, 2023
- Vario-Cup SystemK221794 · Waldemar Link GmbH & Co. KG · Jul 20, 2022
- COPAL exchange G hip spacerK220492 · Heraeus Medical GmbH · Mar 23, 2022
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Oct 30, 2014
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3390
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files