Mecta-C TiPEEK
Intervertebral Fusion Device With Bone Graft, Cervical. 510(k) K142744, from Medacta International (Castel San Pietro, CH). Product code ODP, class 2.
As of Nov 20, 2026, K142744 is an FDA 510(k) held by Medacta International, substantially equivalent on May 7, 2015 after 225 days, with no recalls tied to it in FDA's recall database.
- Review time: 225 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The Mecta-C intervertebral body fusion device is indicated for anterior cervical interbody fusion procedures in skeletally mature patients. The device systems are designed for use with autogenous bone graft to facilitate fusion. One device may be used per intervertebral space. The implants are intended to be used with supplemental spinal fixation.
- Mecta-CK112862 · Medacta International · Dec 19, 2011
- Mectalif TipeekK133192 · Medacta International · Jan 30, 2014
- Mecta-C with titanium markers and Mecta-C TiPEEK with titanium markersK172587 · Medacta International S.A. · Sep 18, 2017
- MectaLIF Anterior Stand-AloneK160605 · Medacta International · Jul 21, 2016
- VariLift-C Cervical Interbody Fusion SystemK262595 · Wenzel Spine, Inc. · Aug 26, 2026
- BluEX Cervical Expandable Cage SystemK262489 · L&K BIOMED Co., Ltd. · Aug 18, 2026
- 3d Cage CervicalK253041 · Fims Co., Ltd. · Jul 23, 2026
- Tritanium® C Anterior Cervical Cage; Tritanium® PL Cage; Tritanium® TL Curved Posterior Lumbar Cage; Aero® -C Cervical…K262061 · Stryker Spine · Jul 17, 2026
- C.A. Medical Interbody Fusion SystemK254130 · C.A. Medical, LLC · Jul 8, 2026
- BluEX Cervical Expandable Cage SystemK260840 · L&K BIOMED Co., Ltd. · May 16, 2026
- Osteomni Spinal Cages SystemK260850 · Osteomni, Inc. · May 12, 2026
- ZSFab Cervical Interbody System and ZSFab Lumbar Interbody SystemK260549 · Zsfab, Inc. · Apr 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 24, 2014
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3080
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files