Medline Silicone Foley Catheter
Catheter, Retention Type, Balloon. 510(k) K142635, from Medline Industries, Inc. (Mundelein, IL). Product code EZL, class 2.
As of Nov 18, 2026, K142635 is an FDA 510(k) held by Medline Industries, Inc., substantially equivalent on Jan 9, 2015 after 114 days, with 1 recall tied to it in FDA's recall database.
- Review time: 114 days
- Recalls: 1
- Cited as a predicate by: 1 device
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFMedline silicone Foley catheters are intended to be placed in the bladder, through the urethra, to drain urine into a collection device. Two-way catheters are intended for urological bladder drainage only. Three-way catheters are intended for urological bladder drainage and bladder irrigation.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Well Lead Silicone and Latex Foley CathetersK082815 · Well Lead Medical Instruments · Oct 8, 2008
Cited as a predicate
1 later 510(k) summary names this device as a predicate- InnoCare Specialty Foley CatheterK241424 · Innocare Urologics, LLC · Sep 18, 2024
Recalls
Recalls FDA ties to K142635, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Started | Recall | Status |
|---|---|---|
| May 28, 2019 | Z-2042-2020Loose silicone particulate was found to be present on the shaft of the silicone catheters. | Terminated |
Other EZL clearances
The newest 510(k)s for the same product code; their median review was 179 days; see every EZL device- OpenFlo Urinary CatheterK261141 · Urolution Medical, Inc. · Oct 6, 2026
- TraumaGuard Intra-Abdominal Pressure-Sensing System (000-0221)K260756 · Sentinel Medical Technologies, · Sep 4, 2026
- Rusch Latex Gold Foley CatheterK262056 · Teleflex Medical Sdn. Bhd. · Aug 5, 2026
- Rusch SoftSimplastic Foley CathetersK252537 · Teleflex Medical Sdn. Bhd. · Jan 20, 2026
- Silicone Urethral Catheter (Silicone Urethral Catheter)K243011 · Guangdong Ecan Medical Co., Ltd. · Jun 16, 2025
- InnoCare Specialty Foley CatheterK241424 · Innocare Urologics, LLC · Sep 18, 2024
- Rüsch Latex Gold Foley CatheterK232469 · Teleflexmedical, Inc. · Aug 1, 2024
- TraumaGuard Intra-abdominal Pressure Sensing SystemK240057 · Sentinel Medical Technologies, LLC · Apr 17, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 17, 2014
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5130
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files