Magna-Fx And Mini Magna-Fx Cannulated Screw Fixation System
Screw, Fixation, Bone. 510(k) K142442, from Zimmer, Inc. (Warsaw, IN). Product code HWC, class 2.
As of Nov 18, 2026, K142442 is an FDA 510(k) held by Zimmer, Inc., substantially equivalent on Oct 3, 2014 after 31 days, with 3 recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 3, 2014
- Review time: 31 days
- Recalls: 3
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Magna-FX Cannulated Bone Screws are indicated for fractures of: • The intracapsular hip, femoral condyles, tibial condyles, ankle, acetabulum, pelvis, and other areas where accurate screw placement is required. • The screw can also be applied to slipped capital femoral epiphysis if image intensification fluoroscopy is used to ascertain the proper position of the screw.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Smith & Nephew Cannulated Screws And WashersK111994 · Smith & Nephew, Inc. · Oct 11, 2011
- Synthes 6.5 Mm Cannulated ScrewK021932 · Synthes (Usa) · Sep 6, 2002
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Arthrex Blunt Tip Screws with Fiber TapeK143702 · Arthrex, Inc. · Apr 9, 2015
Recalls
Recalls FDA ties to K142442, newest first; each opens FDA's recall record| May 4, 2016 | Z-1679-2016A small hole may be present in the inner tray of specific lots of sterile Hip and Trauma Implant Screws. | Terminated |
| Jan 11, 2016 | Z-1144-2016As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013. The affected products are sterile. | Terminated |
| Jan 11, 2016 | Z-1142-2016As a result of the insufficient sealer calibration data for product packaged in firm's Building II between August 2010 and April 2013. The affected products are sterile. | Terminated |
Other HWC Clearances
The newest 510(k)s for the same product code; their median review was 157 days; see every HWC device- Ntegrate Threaded Nail SystemK261961 · Nvision Biomedical Technologies · Oct 14, 2026
- OsteoCentric Technologies Cannulated and Soild Fasteners with NutsK263116 · OsteoCentric Technologies · Oct 2, 2026
- Arthrex Beaming SystemK262975 · Arthrex, Inc. · Sep 25, 2026
- DynaNail Helix® Fixation SystemK260995 · MedShape, Inc. · Sep 23, 2026
- F.A.S.T ScrewK254280 · Steps Ortho · Sep 21, 2026
- ActivaScrew™ Cannulated COMK261057 · Bioretec, Ltd. · Sep 4, 2026
- OsteoCoil™ GT Active Compression SystemK260106 · Flower Orthopedics Corporation DBA Conventus Flower Orthoped · Aug 24, 2026
- Large Compression ScrewsK262344 · TriMed, Inc. · Aug 12, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 2, 2014
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3040
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files