Mosaiq Oncology Information System
Accelerator, Linear, Medical. 510(k) K141572, from Impac Medical Systems, Inc. (Sunnyvale, CA). Product code IYE, class 2.
As of Nov 19, 2026, K141572 is an FDA 510(k) held by Impac Medical Systems, Inc., substantially equivalent on Sep 5, 2014 after 85 days, with 11 recalls tied to it in FDA's recall database.
- Review time: 85 days
- Recalls: 11
- Cited as a predicate by: 1 device
MOSAIQ® is an oncology information system used to manage workflows for treatment planning and delivery. It supports information flow among healthcare facility personnel and can be used wherever radiotherapy and/or chemotherapy are prescribed. Users can configure MOSAIQ® for Medical Oncology use, Radiation Oncology use, or the two together.
- Mosaiq Oncology Information SystemK123230 · Impac Medical Systems, Inc. · Dec 12, 2012
- Ergo++ Version 1.7K080601 · 3D Line Medical Systems S.R.L. · Jun 6, 2008
- MOSAIQ Oncology Information SystemK183034 · Elekta, Inc. · Dec 4, 2018
| Apr 20, 2021 | Z-1783-2021Malware attack | Terminated |
| Sep 24, 2019 | Z-1597-2020The user may inadvertently enter Metric values into Height and Weight fields labeled with US Standard Units. | Open |
| Dec 13, 2018 | Z-0821-2019There is a potential that Wedge IDs were not included in the DICOM RT PLAN sent from the TPS, which will cause the field in MOSAIQ to be created with no wedge. Treatment of a field without the planned wedge will receive… | Open |
| Dec 4, 2018 | Z-0686-2019If a Setup field (CT, kV, MV or MVCT) is created by COPYING a treatment field or another setup field, then the copied field will have the same isocenter as the parent and that isocenter may not be the correct isocenter… | Terminated |
| Aug 3, 2018 | Z-2917-2018Order Status Remains Approved When Should Indicate Complete. | Terminated |
| Jun 30, 2017 | Z-3110-2017The table shift in the vertical direction was inverted during the use of CMA (Couch Move Assistant). Therapy may be directed to an incorrect area. | Terminated |
| Dec 2, 2016 | Z-0731-2017Edits to Particle field definition parameters may not be saved when the field definition window is saved. | Terminated |
| Jun 17, 2016 | Z-2052-2016It is possible that that the selected Plan-of-the Day could be accidently changed by scrolling the mouse wheel up and down and inadvertently selecting another plan. | Terminated |
| Dec 9, 2015 | Z-0557-2016Incorrect drug dosage due to "Age Limit" and patient weight data item issue. | Terminated |
| Nov 24, 2015 | Z-0447-2016First Databank (FDB) is a third party product incorporated into MOSAIQ. FDB routinely modifies drugs in their database to reflect market and formulary changes. In FDB Framework v2.0, those drugs are not being included… | Terminated |
| Jul 1, 2015 | Z-2063-2015A problem exists in MOSAIQ resulting in the incorrect field size being sent to the treatment machine for stereotactic plans using cones. | Terminated |
- AerFrame™ Alignment Laser Box (LBV2)K261865 · Stabilix, LLC · Sep 16, 2026
- EZFluence (RADEZ V2)K261718 · Radformation, Inc. · Aug 31, 2026
- MRIA Radiation Therapy Information System (MRIA)K260733 · Manteia Technologies Co., Ltd. · Aug 26, 2026
- Halcyon, Ethos Radiotherapy System (5.0)K261856 · Varian Medical Systems, Inc. · Aug 3, 2026
- ThinkQA 3K252937 · Dosisoft SA · Jun 12, 2026
- Luna 3DK253004 · Lap GmbH Laser Applikationen · Jun 4, 2026
- AerFrame Patient Immobilization System (AFPIS)K260792 · Stabilix, LLC · May 8, 2026
- Veriqa RT Epid 3DK252258 · Ptw-Freiburg Physikalisch-Technische-Werkstaetten Dr. Pychla · Apr 15, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 12, 2014
- Review panel
- Radiology
- Regulation
- 21 CFR 892.5050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files