Geistlich Mucograft: 15 X 20 MM, 20 X 30 MM, 8 MM Diameter
Barrier, Animal Source, Intraoral. 510(k) K140518, from Geistlich Pharma AG (Washington, DC). Product code NPL, class 2.
As of Nov 18, 2026, K140518 is an FDA 510(k) held by Geistlich Pharma AG, substantially equivalent on Jul 18, 2014 after 140 days, with no recalls tied to it in FDA's recall database.
- Review time: 140 days
- Recalls: 0
- Cited as a predicate by: 3 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFGeistlich Mucograft® and Geistlich Mucograft® Seal are indicated for: - Covering of implants placed in immediate or delayed extraction sockets - Localized gingival augmentation to increase keratinized tissue (KT) around teeth and implants - Alveolar ridge reconstruction for prosthetic treatment - Recession defects for root coverage
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- MucograftK102531 · Ed. Geistlich Soehne AG Fur Chemische Industrie · Nov 17, 2010
- Mucograft Collagen MatrixK073711 · Ed. Geistlich Soehne AG Fuer Chemische Industrie · May 30, 2008
- MucograftK061244 · Ed. Geistlich Soehne AG Fuer Chemische Industrie · Jun 6, 2006
- MucograftK012423 · Ed. Geistlich Soehne AG Fuer Chemische Industrie · Jan 24, 2003
Cited as a predicate
3 later 510(k) summaries name this device as a predicate- Geistlich Mucograft®, Geistlich Mucograft® SealK210280 · Geistlich Pharma AG · Mar 3, 2021
- Geistlich Bio-Gide, Geistlich Bio-Gide Shape, Geistlich Bio-Gide Compressed, Geistlich Bio-Gide Perio, Geistlich…K192042 · Geistlich Pharma AG · Aug 29, 2019
- Geistlich Fibro-GideK171050 · Geistlich Pharma AG · Nov 9, 2017
Other NPL clearances
The newest 510(k)s for the same product code; their median review was 264 days; see every NPL device- Jason membraneK260132 · Botiss Biomaterials GmbH · Nov 8, 2026
- FormaAid Collagen MembraneK260483 · Maxigen Biotech, Inc. · Nov 4, 2026
- OSSIX PlusK262415 · Datum Dental, Ltd. · Oct 29, 2026
- Jason membraneK242817 · Botiss Biomaterials GmbH · Dec 12, 2025
- Augmented Gingival MatrixK250512 · Neo Modulus (Suzhou) Medical Sci-Tech Co., Ltd. · Dec 5, 2025
- Geistlich Mucograft® /Geistlich Mucograft® Seal; Geistlich Fibro-Gide®K252253 · Geistlich Pharma AG · Nov 25, 2025
- Geistlich Bio-Gide; Geistlich Bio-Gide® Shape; Geistlich Bio-Gide® Compressed; Geistlich Bio-Gide® Forte; Geistlich…K251062 · Geistlich Pharma AG · Aug 14, 2025
- SwissMembrane X; SwissMembrane X SocketK250833 · Geistlich Pharma AG · Apr 15, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 28, 2014
- Review panel
- Dental
- Regulation
- 21 CFR 872.3930
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files