Medos Hilite Oxygenator
Oxygenator, Cardiopulmonary Bypass. 510(k) K140177, from Medos Medizintechnik AG (Ann Arbor, MI). Product code DTZ, class 2.
As of Nov 24, 2026, K140177 is an FDA 510(k) held by Medos Medizintechnik AG, substantially equivalent on Feb 18, 2014 after 25 days, with no recalls tied to it in FDA's recall database.
- Review time: 25 days
- Recalls: 0
The Medos hilite 2800 & 2400 LT Hollow Fiber Oxygenators are indicated for use in procedures requiring the extracorporeal oxygenation of and carbon dioxide removal from human blood. It is designed to operate at a blood flow rate of 0.5 to 2.8 liters per minute for the hilite 2800 and 0.5 to 2.4 liters per minute for the hilite 2400 LT for periods of up to six (6.0) hours.
- Medos Hilite Pediatric Oxygenator, Models 2800, 2400 LTK090450 · Gish Biomedical, Inc. · Sep 18, 2009
- HORIZON 8AF (Integrated OXY MODULE 8AF and Horizon CVR) (US5305)K261438 · Eurosets S.R.L · Sep 14, 2026
- Lifemotion Disposable Membrane OxygenatorK253838 · Lifemotion Medical Technology Co., Ltd. · Mar 16, 2026
- Quantum Perfusion Blood Oxygenator ECC VT160-E3 (VT160-E3); Quantum Perfusion Blood Oxygenator ECC VT200-E3 (VT200-E3);…K240934 · Spectrum Medical S.R.L. · Mar 12, 2026
- Horizon AF Plus System (Integrated A.L. One AF Plus OXYGENATOR and Horizon CVR) (US5300); A.L. One AF Plus OXYGENATOR…K250821 · Eurosets S.R.L · Dec 12, 2025
- Trilly Pediatric Oxygenator with Integrated Arterial Filter (US5232)K242503 · Eurosets S.R.L · Nov 24, 2025
- Quantum Perfusion Blood Oxygenator VT75-E1, Quantum Perfusion Blood Oxygenator VT75-E2K231982 · Qura S.R.L · Sep 12, 2024
- Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (BB811); Affinity Fusion Oxygenator…K240666 · Medtronic Perfusion Systems · Jul 10, 2024
- Affinity NT Oxygenator and Uncoated Cardiotomy/ Venous Reservoir (541); Affinity NT Oxygenator with Balance Biosurface…K241352 · Medtronic, Inc. · Jun 12, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jan 24, 2014
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.4350
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files