Universa Percultaneous Drainage Catheter
Catheter, Malecot. 510(k) K140085, from Cook Incorporated (Bloomington, IN). Product code FEW, class 2.
As of Nov 18, 2026, K140085 is an FDA 510(k) held by Cook Incorporated, substantially equivalent on Nov 18, 2014 after 309 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Nov 18, 2014
- Review time: 309 days
- Recalls: 0
- Cited as a predicate by: 4 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Universa® Loop Drainage Catheter Set is intended to provide percutaneous urine drainage from the genitourinary system. The Universa® Malecot Drainage Catheter Set is intended to provide percutaneous urine drainage from the genitourinary system.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Percutaneous Drainage Loop Catheter SetK931195 · Cook Urological, Inc. · Dec 22, 1993
- Vance Percutaneous Malecot NephrostomyK810368 · Vance Products, Inc. · Mar 20, 1981
Cited as a Predicate
4 later 510(k) summaries name this device as a predicate- Cook-Cope Loop Nephrostomy Set, Ultrathane Nephrostomy Set with Mac-Loc, Ultrathane Suprapubic Set with Mac-LocK191498 · Cook Incorporated · Jan 29, 2020
- Percutaneous Neonatal Pigtail Nephrostomy Set, Pediatric Nephrostomy Stent SetK181735 · Cook Incorporated · Mar 27, 2019
- Cook Cystostomy Catheter SetK181097 · Cook Incorporated · Jan 18, 2019
- Malecot Nephrostomy Catheter/Stent SetK180029 · Cook Incorporated · Sep 21, 2018
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 13, 2014
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5090
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files