Gigalaser
Lamp, Infrared, Therapeutic Heating. 510(k) K134017, from Powermedic Aps (Houston, TX). Product code ILY, class 2.
As of Nov 20, 2026, K134017 is an FDA 510(k) held by Powermedic Aps, substantially equivalent on May 2, 2014 after 123 days, with no recalls tied to it in FDA's recall database.
- Review time: 123 days
- Recalls: 0
- Cited as a predicate by: 1 device
GIGALaser 1801 is intended to emit energy in the visible and near infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for a temporary relief of minor muscle and joint pain and stiffness, minor arthritis pain, or muscle spasm; the temporary increase in local blood circulation; and for the temporary relaxation of muscles.
- PowerlaserK070516 · Powermedic Aps · Jul 2, 2007
- Omnilux RedK030426 · Photo Therapeutics Limited · Jul 17, 2003
- Infrared Therapy SystemK142340 · Beijing Huatai Healthcare Technology Co., Ltd. · Dec 2, 2014
- CureLight Medical Diode Laser Systems (CureLight F2-A15; CureLight F2-B15; CureLight F2-A30; CureLight F2-B30;…K253965 · Wuhan PHOMED Technology Company , Ltd. · Mar 19, 2026
- Medical Diode Laser Systems (VELAS II-30B, VELAS II-30A, GBOX-15AB, GBOX-20B, CHEESE II-10B)K242755 · Gigaalaser Company , Ltd. · May 19, 2025
- SIRONA 100 Therapy Laser System (OEM's Model EVANLAS)K231997 · Cure Point Therapeutics, Inc. · Oct 15, 2024
- LED Lip Perfector, model: ZC-05K223642 · Light Tree Ventures Europe B.V. · Mar 9, 2023
- Oliz LTB-1000AK221189 · Ltbio Co., Ltd. · Aug 29, 2022
- CytonPro-5000K213524 · Cytonsys, Inc. · Aug 10, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 30, 2013
- Review panel
- Physical Medicine
- Regulation
- 21 CFR 890.5500
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files