Fastep S10 Hcg Serum/Urine Combo Test
Visual, Pregnancy Hcg, Prescription Use. 510(k) K132834, from Polymed Therapeutics, Inc. (Gaithersburg, MD). Product code JHI, class 2.
As of Nov 18, 2026, K132834 is an FDA 510(k) held by Polymed Therapeutics, Inc., substantially equivalent on Jan 9, 2014 after 121 days, with no recalls tied to it in FDA's recall database.
- Review time: 121 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe Fastep S10 hCG Serum/Urine Combo Test is a rapid visual immunoassay for the qualitative, presumptive detection of human chorionic gonadotropin in human urine or serum specimens. This kit is intended for use as an aid in early detection of pregnancy. This product is only intended for
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Quickvue One-Step Hcg-ComboK020801 · Quidel Corp. · May 17, 2002
Cited as a predicate
1 later 510(k) summary names this device as a predicate- Alltest Pregnancy Rapid Combo Test CassetteK203272 · Hangzhou AllTest Biotech Co., Ltd. · Jan 31, 2022
Other JHI clearances
The newest 510(k)s for the same product code; their median review was 77 days; see every JHI device- Instant-View® hCG Combo II Cassette TestK262299 · Alfa Scientific Designs, Inc. · Sep 22, 2026
- Innovita HCG Pregnancy Rapid Combo TestK241919 · Innovita (Tangshan) Biological Technology Co., Ltd. · Aug 2, 2024
- Alltest Pregnancy Rapid Combo Test CassetteK203272 · Hangzhou AllTest Biotech Co., Ltd. · Jan 31, 2022
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 10, 2013
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1155
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files