Encompass 10/12 Hip Stem
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented. 510(k) K132697, from Ortho Development Corp. (Draper, UT). Product code LPH, class 2.
As of Nov 19, 2026, K132697 is an FDA 510(k) held by Ortho Development Corp., substantially equivalent on Jun 20, 2014 after 295 days, with no recalls tied to it in FDA's recall database.
- Review time: 295 days
- Recalls: 0
This device is intended for use in total hip arthroplasty. The device is intended for uncemented, press-fit use only in cases of: 1. Notably impaired hip joint due to osteoarthritis, rheumatoid arthritis and/or post traumatic arthritis 2. Previously failed surgery 3. Proximal femoral neck fractures or dislocation 4. Idiopathic avascular necrosis of the femoral head 5.
- Encompass 10*17 and 12*17 Extended Press-Fit Hip StemsK053293 · Ortho Development Corp. · Feb 16, 2006
- Primaloc Cementless Hip SystemK953977 · Ortho Development Corp. · Jan 26, 1996
- Ovation 10/12 Hip StemK131022 · Ortho Development Corp. · Oct 16, 2013
- X-Series Bi-Metric Hip Femoral ComponentsK020580 · Biomet, Inc. · Mar 22, 2002
- G7® Acetabular SystemK261453 · Zimmer Biomet · Sep 23, 2026
- Mpact 3D Metal FoamK253630 · Medacta International S.A. · Aug 28, 2026
- TRIVANCE™ Hip StemK254043 · Globus Medical, Inc. · Aug 4, 2026
- Omnifit® 20° Series I Insert;Omnifit® Crossfire® 10° Series II Insert; Constrained Acetabular Insert; Trident®…K261624 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · Jul 10, 2026
- iNSitu Lateralized Acetabular Liners, iNSitu Femoral Stems with Plasma Sprayed CPTi CoatingK243192 · Nextstep Arthopedix, LLC · Jun 5, 2026
- Taperloc® Complete Hip StemK251270 · Biomet, Inc. · May 19, 2026
- G7® Revision Acetabular SystemK252623 · Zimmer, Inc. · Feb 4, 2026
- Mpact 3D Metal Implants Extension – DMLS TechnologyK251043 · Medacta International S.A. · Jan 28, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 29, 2013
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3358
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files