Arca
Skip to content

Cellvizio 100 Series System And Cellvizio System With Confocal Miniprobes and 1 more

Confocal Optical Imaging. 510(k) K132389, from Daniel & Daniel Consulting (Orinda, CA). Product code OWN, class 2.

As of Nov 17, 2026, K132389 is an FDA 510(k) held by Daniel & Daniel Consulting, substantially equivalent on Feb 25, 2014 after 208 days, with no recalls tied to it in FDA's recall database.

  • Substantially equivalent: Feb 25, 2014
  • Review time: 208 days
  • Recalls: 0
  • Cited as a predicate by: 2 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The Cellvizio® 100 Series System with Confocal Miniprobes is a confocal laser system with fiber optic probes that are intended to allow imaging of the internal microstructure of tissues. The Uroflex™ B and CystoFlex™ F Confocal Miniprobes can be used within anatomical tracts, i.e., urinary, including, but not limited to, urethra, bladder, and ureter, accessed through an endoscope or endoscopic…

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

2 later 510(k) summaries name this device as a predicate

Other OWN Clearances

The newest 510(k)s for the same product code; their median review was 196 days; see every OWN device

Record

Type
Traditional
Received
Aug 1, 2013
Review panel
Gastroenterology, Urology
Regulation
21 CFR 876.1500

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.