Evis Exera Iii Video System
Colonoscope And Accessories, Flexible/Rigid. 510(k) K131780, from Olympus Medical Systems Corp. (Center Valley, PA). Product code FDF, class 2.
As of Nov 21, 2026, K131780 is an FDA 510(k) held by Olympus Medical Systems Corp., substantially equivalent on Aug 29, 2013 after 73 days, with 8 recalls tied to it in FDA's recall database.
- Review time: 73 days
- Recalls: 8
- Cited as a predicate by: 5 devices
Endoscopes (GASTROINTESTINAL VIDEOSCOPE GIF-H190, GIF-HQ190, COLONOVIDEOSCOPE CF-HQ190L/I, CF-H190L/I, PCF-H190L/I, PCF-PH190L/I) This instrument is intended to be used with an Olympus video system center, endoscope position detecting unit (for CF-HQ190L/l), light source, documentation equipment, monitor, EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for…
- Evis Exera Iii Video SystemK112680 · Olympus Medical Systems Corporation · Feb 16, 2012
- Disposable Endoscope Valves SystemK232244 · Changzhou Endoclean Medical Device Co., Ltd. · Nov 29, 2023
- PENTAX Medical Video Processor EPK-i8020c, PENTAX Medical Video Upper GI Scope EG29-i20c, PENTAX Medical Video…K231249 · Pentax of America, Inc. · Jul 28, 2023
- EVIS XI Video System Center Olympus CV-1500, Bronchovideoscope Olympus BF-H1100, Bronchovideoscope Olympus BF-1TH1100K222861 · Olympus Medical Systems Corporation · Jun 15, 2023
- Evis X1 Video System Center Olympus CV-1500, Colonovideoscope Olympus CF-HQ1100DL/I, Gastrointestinal Videoscope…K222584 · Olympus Medical Systems Corporation · Apr 26, 2023
- Evis Exera III Colonovideoscope Olympus PCF-H190TL, Evis Exera III Colonovideoscope Olympus PCF-H190TI, Evis Exera III…K192793 · Olympus Medical Systems Corp. · Jul 17, 2020
| Jan 11, 2024 | Z-1210-2024Specific repaired colonovideoscopes were assembled without an adhesive which protects them from certain physical conditions such as high levels of vibration, fluctuation in temperature or severe shock loads. | Open |
| Oct 16, 2023 | Z-0416-2024, Z-0418-2024, Z-0417-2024, Z-0419-2024, Z-0415-2024Specific devices may have an improperly repaired light guide connector due to missing adhesive to secure the suction channel mouthpiece to the scope connector. Issue may result in loss of image, decreased suction, or… | Open |
| Sep 25, 2023 | Z-0341-2024Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for… | Open |
| Sep 14, 2023 | Z-0056-2025Certain serial numbers of the CV-190 do not start up properly because parts that deviated from the specification were assembled into the power supply unit. | Open |
- Triton 1 SystemK260503 · Neptune Medical, Inc. · Sep 3, 2026
- Solo Scope Colonoscope SystemK261015 · Gi View, Ltd. · Aug 21, 2026
- Insufflation Retention Device (IRD) (11173-325-101)K261587 · BPEndo, LLC · Jul 2, 2026
- Disposable Endoscopic Distal AttachmentsK260423 · Yangzhou Fartley Medical Instrument Technology Co., Ltd. · May 28, 2026
- Disposable Distal End Tape HoodK252457 · Shanghai SeeGen Photoelectric Technology Co., Ltd. · Jan 30, 2026
- Robopera (ER-R-002); Robopera (ER-R-003)K244029 · Endorobotics Co., Ltd. · Sep 24, 2025
- FUJIFILM Endoscope Model EC-860P/M; FUJIFILM Endoscope Model EC-860P/L; FUJIFILM Endoscope Model EC-860S/LK243261 · Fujifilm Corporation · May 23, 2025
- Colonovideoscope (CF-EZ1500DL); Colonovideoscope (CF-EZ1500DI); Gastrointestinal Videoscope (GIF-EZ1500)K250432 · Olympus Medical Systems Corporation · May 15, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 17, 2013
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.1500
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files