Subq It! Bioabsorbable Skin Closure System
Staple, Implantable. 510(k) K131563, from Opus Ksd, Inc. (Marlborough, MA). Product code GDW, class 2.
As of Nov 19, 2026, K131563 is an FDA 510(k) held by Opus Ksd, Inc., substantially equivalent on Apr 9, 2014 after 314 days, with no recalls tied to it in FDA's recall database.
- Review time: 314 days
- Recalls: 0
The SubQ It!™ Bioabsorbable Skin Closure System is intended for use in humans for abdominal, thoracic, gynecologic, orthopedic, plastic and reconstructive surgery for the subcuticular closure of skin where an absorbable tissue fastener is desired for temporary tissue approximation. AND/OR
- Insorb Absorbable Staples, Model SP-B20K024117 · Incisive Surgical, Inc. · Apr 22, 2003
- Insorb Absorbable Staple, Model SP-B20K033602 · Incisive Surgical, Inc. · Dec 16, 2003
- Insorb Absorbable Staple, Model 1020K061784 · Incisive Surgical, Inc. · Jul 26, 2006
- Insorb Absorbable Staple, Model 1020, 1025, and Other Product FamiliesK090159 · Incisive Surgical, Inc. · Feb 6, 2009
- Insorb Absorbalbe StapleK120373 · Incisive Surgical, Inc. · Mar 16, 2012
- Tendon AnchorK263461 · Smith & Nephew, Inc. · Oct 27, 2026
- easyEndo™ E-Lite Single Use Powered Endoscopic Staplers; easyEndo™ E-Lite Single Use Powered Endoscopic Staplers with…K254291 · Ezisurg Medical Co., Ltd. · Sep 25, 2026
- ETHICON™ Circular Stapler (CDH21mm); ETHICON™ Circular Stapler (CDH25mm); ETHICON™ Circular Stapler (CDH29mm); ETHICON™…K260196 · Ethicon Endo-Surgery, LLC · May 11, 2026
- Tri-staple 2.0™ Reloads; Endo GIA™ Reloads with Tri-Staple™ Technology; Endo GIA™ Gray Articulating Reloads; Signia™…K253657 · Covidien (Part of Medtronic) · Apr 10, 2026
- ETHICON™ 4000 45mm Compact Stapler (EC3DT45C); ETHICON™ 4000 45mm Standard Stapler (EC3DT45S); ETHICON™ 4000 45mm Long…K252739 · Ethicon Endo-Surgery, LLC · Dec 17, 2025
- ETHICON 4000 60mm Compact Stapler (EC3D60C); ETHICON 4000 60mm Standard Stapler (EC3D60S); ETHICON 4000 60mm Long…K250835 · Ethicon Endo-Surgery, LLC · May 14, 2025
- ECHELON LINEAR™ Stapler 30mm Stapler (GTX30); ECHELON LINEAR™ Stapler 60mm Stapler (GTX60); ECHELON LINEAR™ Stapler…K243276 · Ethicon Endo-Surgery, LLC · Feb 25, 2025
- ECHELON 4000 60mm Compact Stapler (EC3D60C); ECHELON 4000 60mm Standard Stapler (EC3D60S); ECHELON 4000 60mm Long…K241630 · Ethicon Endo-Surgery, LLC · Oct 28, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 30, 2013
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files