Synthes Trochanteric Fixation Nail - Advanced System
Rod, Fixation, Intramedullary And Accessories. 510(k) K131548, from Synthes (USA) Products, LLC (West Chester, PA). Product code HSB, class 2.
As of Nov 17, 2026, K131548 is an FDA 510(k) held by Synthes (USA) Products, LLC, substantially equivalent on Feb 28, 2014 after 274 days, with 9 recalls tied to it in FDA's recall database.
- Substantially equivalent: Feb 28, 2014
- Review time: 274 days
- Recalls: 9
- Cited as a predicate by: 2 devices
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- DePuy Synthes Trauma Orthopedic Nail ImplantsK182783 · DePuy Synthes · Dec 26, 2018
- AUTOBAHN Nailing SystemK171108 · Globus Medical, Inc. · Dec 29, 2017
Recalls
Recalls FDA ties to K131548, newest first; each opens FDA's recall record| Jan 24, 2024 | Z-1239-2024Products not sterilized, sterility cannot be confirmed | Open, Classified |
| Jan 24, 2024 | Z-1240-2024Products not sterilized, sterility cannot be confirmed | Open, Classified |
| Feb 1, 2023 | Z-1247-2023TFNA Femoral Nails labeled and etched as 200mm may measure 170mm in length, and TFNA Femoral Nails labeled and etched as 170mm may measure 200mm in length | Open, Classified |
| Feb 1, 2023 | Z-1246-2023TFNA Femoral Nails labeled and etched as 200mm may measure 170mm in length, and TFNA Femoral Nails labeled and etched as 170mm may measure 200mm in length | Open, Classified |
| Feb 1, 2023 | Z-1248-2023TFNA Femoral Nails labeled and etched as 200mm may measure 170mm in length, and TFNA Femoral Nails labeled and etched as 170mm may measure 200mm in length | Open, Classified |
| Sep 21, 2015 | Z-0126-2016Certain lots of the Screw Inserter may be etched with incorrect graphics. The orientation of the etched image of the oblique angle on the Screw Inserter may not correspond to the tip of the angle of the instrument. | Terminated |
| Jun 10, 2015 | Z-2091-2015The height of one of the three guiding pins of the Helical Blade Inserter for the TFNA is oversized. The Helical Blade Inserter is therefore unable to pass through the Blade/Screw Guide Sleeve (part 03.037.017). | Terminated |
| Apr 9, 2015 | Z-1600-2015TFNA nails from certain lots were assembled with a locking mechanism too close to the top of the nail. Potential patient impact: surgical delay. | Terminated |
| Feb 24, 2015 | Z-1352-2015The guide sleeve has the potential to jam in the Aiming Arms, which may delay disassembly and removal of instruments. | Terminated |
Other HSB Clearances
The newest 510(k)s for the same product code; their median review was 192 days; see every HSB device- Freedom Nail Ankle Fusion SystemK261189 · McGinley Orthopaedic Innovations · Oct 19, 2026
- Pediatric Nailing Platform FemurK261345 · OrthoPediatrics Corp. · Sep 24, 2026
- Pangea Femur Reconstruction SystemK261481 · Stryker GmbH · Jun 29, 2026
- AND Medical Femoral Nail System (PFNA01); AND Medical Femoral Nail System (PFNA02)K253080 · Suzhou and Science & Technology Development Corp. · Jun 18, 2026
- Precice Max System and Precice Ankle Salvage SystemK261651 · NuVasive Specialized Orthopedics · Jun 18, 2026
- Fule Metallic Lockable Intramedullary Nail SystemsK253155 · Beijing Fule Science & Technology Development Co., Ltd. · Jun 17, 2026
- HERA Interlocking Intramedullary Nailing SystemK253046 · ZheJiang Decans Medical Devices Co., Ltd. · Jun 16, 2026
- Fitbone® Transport And Lengthening SystemK260146 · Orthofix Srl · May 19, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 30, 2013
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3020
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files