Hemoglobin A1C, Hemoglobin A1C Calibrators, Hemoglobin A1C Controls

Hemoglobin A1c Test System. 510(k) K130255, from Abbott Laboratories (Abbott Park, IL). Product code PDJ, class 2.

As of Nov 19, 2026, K130255 is an FDA 510(k) held by Abbott Laboratories, substantially equivalent on Feb 28, 2014 after 392 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 392 days
  • Recalls: 3
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Hemoglobin A1c assay is used in clinical laboratories for the quantitative in vitro measurement of percent hemoglobin A1c (NGSP) or HbA1c fraction mmol/mol (IFCC) in human whole blood and hemolysate on the ARCHITECT c 8000 System.Hemoglobin A1c measurements are used as an aid in the diagnosis of diabetes mellitus, as an aid to identify patients who may be at risk for developing diabetes…

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K130255, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Jun 9, 2022Z-1455-2022, Z-1454-2022There is a potential for falsely elevated Hemoglobin %A1c and Hemoglobin A1c results to be generated using the ARCHITECT and Alinity c Hemoglobin A1c assay.Open
Apr 30, 2014Z-0135-2015HbA1c Calibrators LN 4P52-02, lot 45063UQ12 may contain a value sheet for a different HbA1c calibrator lot. If calibrator lot 45063UQ12 is used in the calibration of the HbA1c assay using values from an incorrect…Terminated

Other PDJ clearances

The newest 510(k)s for the same product code; their median review was 269 days; see every PDJ device

Record

Type
Traditional
Received
Feb 1, 2013
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1373

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files