Catheter, Hemodialysis, Implanted. 510(k) K123196, from Covidien (Mansfield, MA). Product code MSD, class 2.

As of Nov 20, 2026, K123196 is an FDA 510(k) held by Covidien, substantially equivalent on Jan 31, 2013 after 112 days, with 25 recalls tied to it in FDA's recall database.

  • Review time: 112 days
  • Recalls: 25+
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Palindromeâ„¢ Precision Symmetric Tip Dual Lumen Catheter is indicated for acute and chronic hemodialysis, apheresis, and infusion. It may be inserted percutaneously or by cut down. Catheters with greater than 40 cm implant length are indicated for femoral placement. The Palindromeâ„¢ Precision RT Reverse-Tunneled Catheter is indicated for acute and chronic hemodialysis, apheresis, and infusion.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K123196, newest first; the 25 newest; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 23, 2025Z-1889-2025, Z-1888-2025, Z-1887-2025, Z-1885-2025, Z-1886-2025Potential breach of sterile barrier packaging.Open
Mar 15, 2024Z-1635-2024, Z-1634-2024Products may not be heparin coated as indicated on the label-leads to a potential loss of benefit due to the absence of the heparin coatingOpen
Jun 8, 2022Z-1315-2022, Z-1313-2022, Z-1314-2022, Z-1312-2022There is a potential leaking condition within the hub of specific chronic dialysis catheters, due to an inter-lumen void in the hub component, which may result in unanticipated fluid return during use.Open
May 28, 2021Z-2372-2021, Z-2371-2021, Z-2374-2021, Z-2373-2021, Z-2375-2021This voluntary withdrawal is being conducted to implement point-of-use labeling on each device and enhancements to the Instructions for Use (IFU).Open
Oct 14, 2015Z-0331-2016, Z-0332-2016, Z-0333-2016, Z-0330-2016, Z-0329-2016Incorrectly packaged with a 90 degree bend at the distal tipTerminated
Apr 23, 2015Z-1869-2015, Z-1909-2015, Z-1870-2015, Z-1868-2015Catheters may not meet antimicrobial specificationTerminated

Other MSD clearances

The newest 510(k)s for the same product code; see every MSD device
  • End CapK210461 · Medical Components Inc (Medcomp) · Sep 14, 2021

Record

Type
Traditional
Received
Oct 11, 2012
Review panel
Gastroenterology, Urology
Regulation
21 CFR 876.5540

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files