Fastener, Fixation, Biodegradable, Soft Tissue. 510(k) K122869, from Depuy Mitek, A Johnson & Johnson Company (Raynham, MA). Product code MAI, class 2.
As of Nov 19, 2026, K122869 is an FDA 510(k) held by Depuy Mitek, A Johnson & Johnson Company, substantially equivalent on Dec 13, 2012 after 85 days, with no recalls tied to it in FDA's recall database.
- Review time: 85 days
- Recalls: 0
The DePuy Mitek MILAGRO BR Interference Screws are designed to attach soft tissues to bone in orthopedic surgical procedures for following indications: Shoulder: Proximal Biceps Tenodesis, Acromio-Clavicular Repair Elbow: Distal Biceps Tenodesis, Ulnar Collateral Ligament repair Knee: Collateral Ligament Repair
- Milagro Interference ScrewsK120589 · Depuy Mitek, A Johnson & Johnson Company · Apr 24, 2012
- DePuy Mitek Milagro Interference Screw Model 231803, 231804, 231807, 231809K103831 · Depuy Mitek, A Johnson & Johnson Company · Jul 21, 2011
- Milagro Interference ScrewK060830 · Depuy Mitek, A Johnson & Johnson Company · Jun 15, 2006
- Biocryl Rapide Interference ScrewK032717 · Mitek Worldwide · Mar 31, 2004
- Arthrex Tenodesis FamilyK051726 · Arthrex, Inc. · Sep 27, 2005
- Arthrex Tenodesis Screw FamilyK041356 · Arthrex, Inc. · Nov 4, 2004
- 4.0 MM Arthrex Bio-Tendoesis Screw, Model AR-1540B; 5.5 MM Arthrex Bio-Tenodesis Screw, Models AR-1555BK020043 · Arthrex, Inc. · Apr 2, 2002
- SF Push-in AnchorK263244 · Surgical Fusion Technologies GmbH · Nov 5, 2026
- Arthrex Bioabsorbable PushLock Suture AnchorsK262357 · Arthrex, Inc. · Aug 7, 2026
- Arthrex Bioabsorbable PushLock Suture AnchorsK253931 · Arthrex, Inc. · May 28, 2026
- SF Push-in AnchorK260294 · Surgical Fusion Technologies GmbH · Mar 27, 2026
- OSSIOfiber® Suture AnchorK254055 · OSSIO , Ltd. · Feb 24, 2026
- Biosteon® ScrewK251680 · Biocomposites, Ltd. · Feb 17, 2026
- BioBrace® Extra-Articular Ligament Augmentation KitK252946 · Conmed Corporation · Oct 15, 2025
- OSSIOfiber® Interference ScrewK252022 · OSSIO , Ltd. · Aug 19, 2025
- Japan approved MILAGRO Interference Screw, the same brandPMDA · Sep 6, 2013
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 19, 2012
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3030
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files