Mammomal Inspiration
Full Field Digital, System, X-Ray, Mammographic. 510(k) K122286, from Siemens Medical Solutions USA, Inc. (Mavern, PA). Product code MUE, class 2.
As of Nov 20, 2026, K122286 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., substantially equivalent on Feb 22, 2013 after 207 days, with 5 recalls tied to it in FDA's recall database.
- Review time: 207 days
- Recalls: 5
- Cited as a predicate by: 2 devices
The Mammomat Inspiration system is intended for mammography exams, screening, diagnosis, and stereotactic biopsies under supervision of medical professionals. Mammographic images can be interpreted by either hardcopy film or softcopy workstation.
- Siemens Mammomat Novationdr Full Field Digital Mammography SystemP030010 · Siemens Medical Solution · Aug 20, 2004
- Mammomat Fusion with Stereotactic BiopsyK163252 · Siemens Medical Solutions USA, Inc. · Jan 10, 2017
- MAMMOMAT FusionK151645 · Siemens Medical Solutions USA, Inc. · Sep 14, 2015
| Jan 11, 2017 | Z-1118-2017Software error | Terminated |
| Oct 28, 2014 | Z-0523-2015It was determined that if the Mammomat Inspiration system is not secured to the floor (per customer request) and monitors are positioned too far from the table top, there is a potential risk that the Acquisition… | Terminated |
| Sep 18, 2014 | Z-0086-2015The stereo biopsy devices for Mammomat Inspiration mammography systems might have integrated a safety switch which causes a failure of the functionality. The pin implemented in the safety switch may not put enough… | Terminated |
| Apr 25, 2014 | Z-1638-2014There is a potential and possible hazard to the user when using the MAMMOMAT Inspiration PC monitor at the control desk, in that the holder of the PC monitor can break causing an unstable monitor to fall causing… | Terminated |
| Feb 28, 2013 | Z-1694-2013Firm became aware of an unintended behavior when using the Mammomat Inspiration. The possibility exists that a malfunction may occur during Stereo or Tomo acquisitions if the tomo clutch was incorrectly adjusted.… | Terminated |
- I-View®K254090 · Hologic, Inc. · Sep 2, 2026
- MAMMOMAT B.brilliant (11372950)K253678 · Siemens Medical Solutions USA, Inc. · Jun 18, 2026
- Bellalun 2D (VDMS-1000S)K254092 · Vieworks Co., Ltd. · May 28, 2026
- Senographe Pristina; SenoBright HD; Pristina Serena; Pristina Serena BrightK260087 · GE Medical Systems SCS · Mar 24, 2026
- HestiaK243420 · Genoray Co., Ltd. · Jul 17, 2025
- 2430TCA with Xmaru WK243849 · Rayence Co., Ltd. · Mar 12, 2025
- Vivix-MK241113 · Vieworks Co., Ltd. · Jan 16, 2025
- MAMMOMAT B.brilliantK233539 · Siemens Medical Solutions USA, Inc. · Mar 27, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 30, 2012
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1715
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files