Gibralt Occipital Plate Screws, Set Screw, Gibralt Occipital System Articulating Rod, Gibralt Occipital Plates
Appliance, Fixation, Spinal Interlaminal. 510(k) K121877, from Exactech, Inc. (Gainesville, FL). Product code KWP, class 2.
As of Nov 20, 2026, K121877 is an FDA 510(k) held by Exactech, Inc., substantially equivalent on Feb 12, 2013 after 229 days, with no recalls tied to it in FDA's recall database.
- Review time: 229 days
- Recalls: 0
- Cited as a predicate by: 1 device
When used with the Gibralt Spine System, the Gibralt Occipital Spine System is intended to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput - T3). The Gibralt Occipital Spine System is indicated for the following: DDD (neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, spinal stenosis…
- Mountaineer Oct Spinal SystemK110353 · Depuy Spine, Inc. · Apr 7, 2011
- Sumit Oct Spinal System and Mountaineer Oct Spinal SystemK042508 · Depuy Spine, Inc. · Oct 7, 2004
- Summit Oct Spinal SystemK041203 · Depuy Spine, Inc. · Jun 2, 2004
- Vertex Reconstruction System, Vertex Select Reconstruction SystemK110522 · Medtronic Sofamor Danek USA, Inc. · Apr 1, 2011
- Vertex Reconstruction System, Vertex Select Reconstruction SystemK091365 · Medtronic Soafamor Danek · Aug 6, 2009
- Vertex Reconstruction System, Vertex Select Reconstruction SystemK090714 · Medtronic Sofamor Danek · Apr 17, 2009
- Vertex Recontruction System, Vertex Select Reconstruction SystemK082728 · Medtronic Sofamor Danek USA, Inc. · Jan 16, 2009
- Nexlink Oct System, Model 7000 SeriesK090060 · Abbott Spine, Inc. · Jun 2, 2009
- Streamline Oct Occipito-Cervico-Thoracic SystemK133374 · Pioneer Surgical Technology, Inc. (Rti Surgical, I · Mar 19, 2014
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 28, 2012
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files