Nimbus Electrosurgical Radiofrequency Multitined Expandable Electrode
Probe, Radiofrequency Lesion. 510(k) K121773, from Biomerics (Salt Lake City, UT). Product code GXI, class 2.
As of Nov 20, 2026, K121773 is an FDA 510(k) held by Biomerics, substantially equivalent on Sep 21, 2012 after 95 days, with no recalls tied to it in FDA's recall database.
- Review time: 95 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The NIMBUS Electrosurgical Radiofrequency Multitined Expandable Electrode is intended for use in radiofrequency (RF) heat lesion procedures for relief of pain using a compatible RF Generator with rated voltage less than or equal to 850V.
- Vesta RF CannulaK190259 · Biomerics · Feb 7, 2020
- Diros OWL Sterile Single Use TridentTM R.F. Insulated Cannulae,Models DTR and DTRHK150371 · Diros Technology, Inc. · Jul 30, 2015
- Disposable Radiofrequency CannulaK253907 · Abbott Medical · Apr 16, 2026
- STAR RF Ablation SystemK251802 · Merit Medical Systems, Inc. · Feb 13, 2026
- OneRF Trigeminal Nerve Radiofrequency ProbesK251243 · Neuroone Medical Technologies Corp. · Aug 15, 2025
- Disposable RF Electrode (RFDE-5/RFDE-10/RFDE-15/RFDE-20)K242841 · Abbott Medical · May 27, 2025
- OptaBlate BVN Intraosseous Nerve Ablation System (10mm Probe Single Kit); OptaBlate BVN Intraosseous Nerve Ablation…K250213 · Stryker Instruments · May 15, 2025
- RF CannulaK241367 · Shanghai Samedical & Plastic Instruments Co., Ltd. · Jan 23, 2025
- Intracept Intraosseous Nerve Ablation SystemK222281 · Relievant Medsystems, Inc. · Oct 26, 2022
- Intracept Intraosseous Nerve Ablation SystemK213836 · Relievant Medsystems, Inc. · Mar 11, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Jun 18, 2012
- Review panel
- Neurology
- Regulation
- 21 CFR 882.4725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files