Epi Mini Ecg Portable Health Monitoring System (Epi Mini)
Transmitters And Receivers, Electrocardiograph, Telephone. 510(k) K121628, from Epi Mobile Health Solutions (S) Pte, Ltd. (Washington, DC). Product code DXH, class 2.
As of Nov 17, 2026, K121628 is an FDA 510(k) held by Epi Mobile Health Solutions (S) Pte, Ltd., substantially equivalent on Jun 25, 2013 after 386 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jun 25, 2013
- Review time: 386 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe EPI Mini Portable ECG Recorder (“EPI Mini”) is intended for use with a patient’s smartphone to record, store and wirelessly transmit physiological data to a remote server. It is indicated for individuals who are at risk for cardiac disease, experience transient symptoms suggesting possible cardiac arrhythmia or have existing heart conditions.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Reka E100K111438 · Reka Pte, Ltd. · Sep 12, 2011
- Fidelity 200 Cardiac Event RecorderK071228 · Signalife, Inc. · Nov 21, 2007
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- ZIO SR ECG Monitoring ServiceK143513 · iRhythm Technologies, Inc. · Jun 19, 2015
Other DXH Clearances
The newest 510(k)s for the same product code; their median review was 314 days; see every DXH device- PreemptiveAI Clinical SDKK250233 · Measure Labs, Inc. (Dba Preemptiveai, Inc.) · Feb 13, 2026
- HeartBeam AIMIGo with 12-L ECG Synthesis Software SystemK250258 · Heartbeam, Inc. · Dec 8, 2025
- MEMO Patch M (MPT-E08R-UNC01)K243438 · Huinno Co., Ltd. · Dec 5, 2025
- Hexoskin Medical System (7100-00016)K243981 · Carre Technologies, Inc. · Nov 18, 2025
- VitalSigns 1-Lead Holter (VSH101)K243003 · VitalSigns Technology Co., Ltd. · Jun 17, 2025
- Qt Ecg (QTERD100)K233521 · QT Medical, Inc. · Dec 6, 2023
- V-Patch Cardiac MonitorK222842 · Shandong Corecare Technology Limited · Oct 20, 2022
- Qt EcgK220795 · QT Medical, Inc. · Sep 26, 2022
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 4, 2012
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2920
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files