Gridlock Plating System
Plate, Fixation, Bone. 510(k) K121452, from Trilliant Surgical, Ltd. (Round Rock, TX). Product code HRS, class 2.
As of Nov 17, 2026, K121452 is an FDA 510(k) held by Trilliant Surgical, Ltd., substantially equivalent on Aug 20, 2012 after 96 days, with 4 recalls tied to it in FDA's recall database.
- Substantially equivalent: Aug 20, 2012
- Review time: 96 days
- Recalls: 4
- Cited as a predicate by: 4 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Gridlock Plating System is intended for use in trauma and reconstructive procedures of the small bones in the hand/foot, ankle, and other bones appropriate for the size of the device. The plates and screws are intended for single use only.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Osteomed Foot Plating SystemK091614 · Osteomed LP · Sep 10, 2009
Cited as a Predicate
4 later 510(k) summaries name this device as a predicate- Minimally Invasive Bunion Plating SystemK172178 · Trilliant Surgical, Ltd. · Nov 16, 2017
- Gridlock Ankle Plating SystemK160177 · Trilliant Surgical, Ltd. · Apr 22, 2016
- Gridlock Plating SystemK130964 · Trilliant Surgical, Ltd. · May 8, 2013
- Gridlock Plating SystemK123525 · Trilliant Surgical, Ltd. · Feb 15, 2013
Recalls
Recalls FDA ties to K121452, newest first; each opens FDA's recall record| Jul 19, 2018 | Z-1609-2020Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018. | Terminated |
| Aug 6, 2015 | Z-2490-2015The affected parts subject to the recall are out of specification, resulting in in the loss of the optimal locking screw functionality of the plates. The thread depth of the screw holes is insufficient, potentially… | Terminated |
| Jul 31, 2015 | Z-2738-2015Gridlock screw driver bits for the Gridlock Plating System were identified to be out of specification and have the potential for shallow engagement between the driver and the screw, resulting in an increased likelihood… | Terminated |
| Jul 20, 2015 | Z-2456-2015The cannulation of the Concave and Convex Reamer Heads may be too small to allow the Guide Pin to freely pass through. | Terminated |
Other HRS Clearances
The newest 510(k)s for the same product code; their median review was 79 days; see every HRS device- Arthrex Plates, Screws and Pins, and WashersK263602 · Arthrex, Inc. · Oct 29, 2026
- Trochlear Salvage Plating SystemK261135 · Skeletal Dynamics, Inc. · Oct 26, 2026
- ANTHEM Fracture SystemK262779 · Globus Medical, Inc. · Oct 23, 2026
- Tempo Plating SystemK263407 · Pace Surgical · Oct 23, 2026
- Park's Pectus SystemK263269 · Tdm Co., Ltd. · Oct 15, 2026
- TDM Large Bone Plate and Screw SystemK261611 · Tdm Co., Ltd. · Oct 2, 2026
- Alians ForearmK262649 · Newclip Technics · Sep 28, 2026
- ProRib Fixation SystemK261892 · Costa Surgical, Inc. · Sep 23, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 16, 2012
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3030
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files