Smith & Nephew, Inc. Total Knee System Instrumentation

Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer. 510(k) K121393, from Smith & Nephew, Inc. (Memphis, TN). Product code MBH, class 2.

As of Nov 19, 2026, K121393 is an FDA 510(k) held by Smith & Nephew, Inc., substantially equivalent on Aug 7, 2012 after 90 days, with 4 recalls tied to it in FDA's recall database.

  • Review time: 90 days
  • Recalls: 4
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Smith & Nephew Hinge Total Knee Instruments are accessory devices and are intended to be used to assist in the implantation of Smith & Nephew Hinge Total Knee Systems and their cleared Indications for Use. Indications for Hinged Total Knees 1. Rheumatoid arthritis. 2. Post-traumatic arthritis, osteoarthritis, or degenerative arthritis. 3.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K121393, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Dec 16, 2019Z-0878-2020Multiple lots of LEGION AP Femoral Cutting Blocks were manufactured with an oversize green plunger hole and therefore do not meet their design specifications.Open
Sep 18, 2018Z-0200-2019One lot of the Legion AP femoral cutting block, size 6, was manufactured with an oversized spring.Terminated
May 4, 2018Z-2163-2018One lot of GENESIS II 13 mm tibial punches are 2 mm smaller than specification.Terminated
Apr 9, 2018Z-1902-2018A single lot of GENESIS II FEMORAL FIVE DEGREE VALGUS BUSHING due to a laser mark labeling error. The left valgus bushing was incorrectly laser marked as right and vice versa.Terminated

Other MBH clearances

The newest 510(k)s for the same product code; their median review was 153 days; see every MBH device

Record

Type
Traditional
Received
May 9, 2012
Review panel
Orthopedic
Regulation
21 CFR 888.3565

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files