Mtf New Bone Void Filler
Filler, Bone Void, Calcium Compound. 510(k) K121313, from Musculoskeletal Transplant Foundation (Edison, NJ). Product code MQV, class 2.
As of Nov 17, 2026, K121313 is an FDA 510(k) held by Musculoskeletal Transplant Foundation, substantially equivalent on Jan 11, 2013 after 254 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jan 11, 2013
- Review time: 254 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe MTF New Bone Void Filler is intended for use as a Demineralized Bone Matrix for voids or gaps that are not intrinsic to the stability of the bony structure. The MTF New Bone Void Filler is indicated for treatment of surgically created osseous defects or osseous defects created from traumatic injury.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Mtf New Bone Void FillerK110003 · Musculoskeletal Transplant Foundation · Oct 13, 2011
- Mtf New Bone Voild FillerK113167 · Musculoskeletal Transplant Foundation · Jan 24, 2012
- Dbx Demineralized Bone Matrix Putty, Bone Matrix Paste And Bone Matrix MixK040262 · Musculoskeletal Transplant Foundation · Mar 17, 2005
- Dbx Demineralized Bone Matrix PuttyK103784 · Musculoskeletal Transplant Foundation · Apr 13, 2011
- Dbx Demineralized Bone Matrix PuttyK103795 · Musculoskeletal Transplant Foundation · Apr 13, 2011
- Dbx StripK042829 · Musculoskeletal Transplant Foundation · Jan 13, 2006
- Dbx StripK062205 · Musculoskeletal Transplant Foundation · Feb 5, 2007
Other MQV Clearances
The newest 510(k)s for the same product code; their median review was 96 days; see every MQV device- Mg OSTEOREVIVE;Mg OSTEOCRETEK262230 · Bone Solutions, Inc. · Sep 11, 2026
- Device 300419 StripK260364 · Geistlich Pharma AG · Jun 2, 2026
- JAZBI Resorbable Bone Void FillerK252797 · Sdip Innovations Pty, Ltd. · May 26, 2026
- Vitoss® BiModal Bioactive Bone Graft Substitute Foam Strip; Vitoss® BiModal Bioactive…K261008 · Stryker Spine · Apr 24, 2026
- Adaptos®Fuse Bone GraftK253524 · Biomendex OY · Feb 17, 2026
- FIBERGRAFT BG Putty GPS Bone Graft Substitute FIBERGRAFT BG Putty Bone Graft Substitute…K253147 · Prosidyan, Inc. · Oct 22, 2025
- Mg OSTEOINJECT; Mg OSTEOREVIVE; Mg OSTEOCRETEK251522 · Bone Solutions, Inc. · Oct 13, 2025
- Allomatrix (Allomatrix Injectable Putty; Allomatrix C; Allomatrix DR; Allomatrix Custom)K252085 · Wright Medical Technology, Inc. (Stryker Corporation) · Sep 30, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 2, 2012
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3045
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files