Dlp Single Stage Venous Cannula, Dlp Right Angle Single Stage Venous Cannula, Dlp Single Stage Venous Cannula With Right
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass. 510(k) K120988, from Medtronic, Inc. (Minneapolis, MN). Product code DWF, class 2.
As of Nov 19, 2026, K120988 is an FDA 510(k) held by Medtronic, Inc., substantially equivalent on Jul 25, 2012 after 114 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 114 days
- Recalls: 2
- Cited as a predicate by: 2 devices
These cannulae are intended for collection of venous blood from the right side of the heart via the superior and inferior vena cava during cardiopulmonary bypass surgery up to six hours of less.
- Novametrix 850 Transcutaneous OxygenK842374 · Novametrix Medical Systems, Inc. · Sep 17, 1984
- Malleable Single Stage Venous Cannula, Models 68112-68140 (15 Total Codes)K022272 · Medtronic Cardiac Surgical Products · Jan 8, 2003
- Affinity CP Centrifugal Pump, Resting Heart Sys.,Myotherm Cardioplegia Deliv.,Affinity Hollow Fiber Oxygenator,AafK111972 · Medtronic, Inc. · Jul 27, 2011
- Venous Return Catheter SS-1K845045 · Dlp, Inc. · Apr 3, 1985
- MC2 Two-Stage Venous Cannula, Oval MC2 Two-Stage Venous Cannula, Thin Wall Two-Stage Venous Cannula, MC2X Three-Stage VeK140165 · Medtronic, Inc. · May 20, 2014
- Dlp Retrograde Coronary Sinus Perfusion Cannula Without Pressure Monitoring Line, Dlp Retrograde Coronary Sinus PerfusioK132995 · Medtronic, Inc. · Oct 31, 2013
| Jul 9, 2024 | Z-3128-2024During manufacturing, DLP Single Stage Venous Cannulae - straight tip (Model 66118) was incorrectly placed into a product labeled as DLP Single Stage Venous Cannulae - right angle metal tip (Model 67312). | Open |
| Feb 19, 2013 | Z-0908-2013Potential for uncharacteristically rough metal edges to occur along the inner diameter of the metal tip side ports of the cannula. | Terminated |
- AngioVac F1885K263076 · AngioDynamics, Inc. · Oct 30, 2026
- DLP™ Coronary Ostial CannulaeK263596 · Medtronic, Inc. · Oct 29, 2026
- Dual Stage Venous CannulaeK263092 · Sorin Group Italia S.R.L. · Oct 1, 2026
- Tri Stage Venous CannulaeK262052 · Sorin Group Italia S.R.L. · Sep 28, 2026
- Elongated One-Piece Arterial (EOPA) 3D™ Arterial CannulaeK260195 · Medtronic, Inc. · Apr 23, 2026
- Venous Return CannulaeK250937 · LivaNova USA, Inc. · Mar 11, 2026
- Smart Reactors Camouflage Coated Extracorporeal Cardiopulmonary Tubing Set (SR180C)K260043 · Smart Reactors · Feb 23, 2026
- Retrograde Coronary Sinus Perfusion CannulaeK253203 · Medtronic, Inc. · Feb 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Apr 2, 2012
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.4210
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files