Mtf Fascia
Mesh, Surgical, Collagen, Orthopaedics, Reinforcement Of Tendon. 510(k) K120479, from Musculoskeletal Transplant Foundation (Washington, DC). Product code OWY, class 2.
As of Nov 17, 2026, K120479 is an FDA 510(k) held by Musculoskeletal Transplant Foundation, substantially equivalent on Nov 8, 2012 after 266 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Nov 8, 2012
- Review time: 266 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFMTF Fascia is intended for the reinforcement of soft tissues repaired by sutures or suture anchors during tendon repair surgery including reinforcement of rotator cuff, patellar, Achilles, biceps, quadriceps, or other tendons.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Orthadapt PrK090288 · Pegasus Biologics, Inc. · May 5, 2009
- Synthasome X-RepairK083307 · Synthasome, Inc. · Mar 27, 2009
Other OWY Clearances
The newest 510(k)s for the same product code; their median review was 120 days; see every OWY device- Arthrex SpeedFLEX ImplantK251690 · Arthrex, Inc. · Sep 30, 2025
- Tapestry Biointegrative ImplantK252647 · Embody, Inc. · Sep 19, 2025
- TYBR Collagen GelK250109 · Tybr Health · Jun 6, 2025
- Tendon Protect (50242)K243843 · Kerecis Limited · Jun 4, 2025
- REGENETEN Bioinductive ImplantK242631 · Smith & Nephew Inc., Endoscopy Div. · Nov 26, 2024
- Regeneten Bioinductive ImplantK222501 · Smith and Nephew, Inc. · May 11, 2023
- Tapestry Biointegrative ImplantK220867 · Embody, Inc. · May 23, 2022
- Tapestry Biointegrative ImplantK212306 · Embody, Inc. · Nov 2, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 16, 2012
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.3300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files