Arca
Skip to content

Ortholoc 3DI Hallux System

Plate, Fixation, Bone. 510(k) K120359, from Wrightmedicaltechnologyinc (Arlington, TN). Product code HRS, class 2.

As of Nov 17, 2026, K120359 is an FDA 510(k) held by Wrightmedicaltechnologyinc, substantially equivalent on May 3, 2012 after 87 days, with 2 recalls tied to it in FDA's recall database.

  • Substantially equivalent: May 3, 2012
  • Review time: 87 days
  • Recalls: 2
  • Cited as a predicate by: 10 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The ORTHOLOC™ 3Di Hallux System is intended for use in stabilization and fixation of fresh fractures, revision procedures, joint fusion, and reconstruction of bones of the feet and toes. Specific examples include: • First metatarsal osteotomies for hallux valgus correction including: ○ Opening base wedge osteotomy ○ Closing base wedge osteotomy o Crescentic osteotomy ○ Proximal Chevron osteotomy…

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

10 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K120359, newest first; each opens FDA's recall record
Apr 10, 2023Z-1467-2023Two lots of Ortholoc 3Di Fusion plates contain incorrect dorsiflexion descriptions laser marked on the parts.Open, Classified
Apr 10, 2023Z-1466-2023Two lots of Ortholoc 3Di Fusion plates contain incorrect dorsiflexion descriptions laser marked on the parts.Open, Classified

Other HRS Clearances

The newest 510(k)s for the same product code; their median review was 79 days; see every HRS device

Record

Type
Traditional
Received
Feb 6, 2012
Review panel
Orthopedic
Regulation
21 CFR 888.3030

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.