Rapicide OPA-28
Sterilant, Medical Devices. 510(k) K120306, from Minntech Corp. (Minneapolis, MN). Product code MED, class 2.
As of Nov 21, 2026, K120306 is an FDA 510(k) held by Minntech Corp., substantially equivalent on Sep 27, 2012 after 239 days, with no recalls tied to it in FDA's recall database.
- Review time: 239 days
- Recalls: 0
- Cited as a predicate by: 1 device
Rapicide OPA-28 is a high level disinfectant solution for reprocessing of heat sensitive semi-critical medical devices for which sterilization is not suitable. Rapicide OPA-28 may be used at or above its minimum recommended concentration (MRC) of 0.35% OPA as determined by Rapicide OPA-28 test strips in manual device reprocessing with an immersion time of at least 10 minutes at a minimum…
- Opaciden SolutionK070627 · Ciden Technologies, LLC · Aug 2, 2007
- 0.55% Orth-Phthalaldehyde SolutionK030004 · Advanced Sterilization Products · Feb 27, 2003
- Medivators 5 Minute High-Level DisinfectantK993042 · Medivators, Inc. · Aug 17, 2000
- CS-Medical TD 100 Disinfector with TD-5 and TD-8 High Level Disinfectants, CS Medical TD-5 High Level Disinfectant, CS…K160921 · Cs Medical, LLC · Nov 3, 2016
- Endox High Level DisinfectantK254094 · Whiteley USA, Inc. · Oct 16, 2026
- SYSTEM 1E Liquid Chemical Sterilant Processing System, Model P6700; SYSTEM 1 endo Liquid Chemical Sterilant Processing…K251666 · STERIS Corporation · Apr 8, 2026
- SYSTEM 1E Liquid Chemical Sterilant Processing System (P6500); SYSTEM 1 endo Liquid Chemical Sterilant Processing…K232914 · STERIS Corporation · Oct 3, 2023
- SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900K230582 · STERIS Corporation · Mar 28, 2023
- SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model…K222615 · STERIS Corporation · Sep 28, 2022
- SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model…K211607 · STERIS Corporation · Sep 7, 2021
- SYSTEM 1E Liquid Chemical Sterilant Processing System, SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model…K210737 · STERIS Corporation · May 12, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 1, 2012
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.6885
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files