Stents, Drains And Dilators For The Biliary Ducts. 510(k) K112994, from Boston Scientific Corporation (Marlboro, MA). Product code FGE, class 2.

As of Nov 17, 2026, K112994 is an FDA 510(k) held by Boston Scientific Corporation, substantially equivalent on Feb 10, 2012 after 126 days, with 6 recalls tied to it in FDA's recall database.

  • Substantially equivalent: Feb 10, 2012
  • Review time: 126 days
  • Recalls: 6
  • Cited as a predicate by: 10 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The CRE™ Wireguided Balloon Dilatation Catheter is indicated for use in adult and adolescent populations to endoscopically dilate strictures of the alimentary tract. It is also indicated in adults for endoscopic dilatation of the Sphincter of Oddi with or without prior sphincterotomy.

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

10 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K112994, newest first; each opens FDA's recall record
May 21, 2026Z-2628-2026Potential sterile breach of the pouches in which devices are packaged.Open, Classified
May 21, 2026Z-2631-2026Potential sterile breach of the pouches in which devices are packaged.Open, Classified
May 21, 2026Z-2630-2026Potential sterile breach of the pouches in which devices are packaged.Open, Classified
May 21, 2026Z-2627-2026Potential sterile breach of the pouches in which devices are packaged.Open, Classified
May 21, 2026Z-2626-2026Potential sterile breach of the pouches in which devices are packaged.Open, Classified
May 21, 2026Z-2629-2026Potential sterile breach of the pouches in which devices are packaged.Open, Classified

Other FGE Clearances

The newest 510(k)s for the same product code; their median review was 162 days; see every FGE device

Record

Type
Traditional
Received
Oct 7, 2011
Review panel
Gastroenterology, Urology
Regulation
21 CFR 876.5010

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files