Ac Wound Treatment System
Negative Pressure Wound Therapy Powered Suction Pump. 510(k) K111949, from Nanovibronix, Inc. (Crofton, MD). Product code OMP, class 2.
As of Nov 19, 2026, K111949 is an FDA 510(k) held by Nanovibronix, Inc., substantially equivalent on Jun 29, 2012 after 357 days, with no recalls tied to it in FDA's recall database.
- Review time: 357 days
- Recalls: 0
807.92(a)(5) AC Wound Management System is indicated for patients who would benefit from a suction device (negative pressure) to help promote wound healing by removing fluids, including irrigation and body fluids, wound exudates, and infectious materials.
- Renasys Go Negative Pressure Wound TherapyK083375 · Smith & Nephew, Inc. · Feb 25, 2009
- Wound VOX NPWT System (V1-01-01); Wound VOX 300ml Collection Canister & Supply Tubing (CC-00-03); Wound VOX Y-Connector…K262232 · Bechtel Medical, Inc. · Nov 6, 2026
- RENASYS-G 15Fr Channel Drain Gauze Dressing Kit (66802257); RENASYS 15Fr Channel Drain Accessory Kit (66802253)K260306 · Smith & Nephew Medical, Ltd. · Oct 30, 2026
- RENASYS ABDO SHIELD Temporary Abdominal Closure Kit (66807747)K261982 · Smith & Nephew Medical, Ltd. · Oct 23, 2026
- MeCare Alpha (MCA2019)K260426 · IVT Medical, Ltd. · Oct 8, 2026
- RENASYS DYNAFLOW Kit (66807741)K261338 · Smith & Nephew Medical, Ltd. · Sep 11, 2026
- ConvaVAC™ Negative Pressure Wound Therapy SystemK253263 · Convatec Limited, Gdc Building · Jun 24, 2026
- Curasys 2 (EMDN0003)K253199 · CG Bio Co., Ltd. · Jun 23, 2026
- Renasys Edge (66803126)K260646 · Smith & Nephew Medical, Ltd. · May 27, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 8, 2011
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4780
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files