Joule Clearsense Laser System
Lasers For Temporary Increase Of Clear Nail In Patients With Onychomycosis. 510(k) K111483, from Sciton, Inc (Palo Alto, CA). Product code PDZ, class 2.
As of Nov 17, 2026, K111483 is an FDA 510(k) held by Sciton, Inc, substantially equivalent on Dec 7, 2011 after 190 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Dec 7, 2011
- Review time: 190 days
- Recalls: 0
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe JOULE ClearSense Laser System is indicated for ablation, vaporization, incision, excision and coagulation of soft tissue, including: • Matrixectomy • Periungual and subengual warts • Planter warts Radical nail excision • Neuromas It is also indicated for use for the temporary increase of clear nail in patients with onychomycosis (e.g., dermatophytes Trichophyton rubrum and T.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Cutera Genesisplus Laser SystemK103626 · Cutera, Inc. · Apr 5, 2011
- Pinpointe FootlaserK093547 · Pinpointe USA, Inc. · Oct 15, 2010
- Pinpointe Footlaser Model 6W, 30W, 100WK093545 · Incisive, Inc. (Formerly Named Incisive, LLC) · Oct 15, 2010
Other PDZ Clearances
The newest 510(k)s for the same product code; their median review was 90 days; see every PDZ device- Medicell Mycosis Laser (MCML24004)K253960 · Medicell Healthcare Co.,LTD · Mar 9, 2026
- Onycho Laser VK241116 · Terasysd&C, Inc. · Jul 22, 2024
- TFX-LT2000 Therapy LightK211265 · Toefx, Inc. · Nov 17, 2022
- AF LaserK221363 · ShenB Co., Ltd. · Jul 20, 2022
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 31, 2011
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.4810
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files