Arca
Skip to content
Tools
Tools

Uni-Vent (R) Model 731 Series Portable Critical Care Ventilator

Ventilator, Continuous, Facility Use. 510(k) K111473, from Impact Instrumentation, Inc. (West Caldwell, NJ). Product code CBK, class 2.

As of Nov 20, 2026, K111473 is an FDA 510(k) held by Impact Instrumentation, Inc., substantially equivalent on Feb 16, 2012 after 265 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 265 days
  • Recalls: 2
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

(the text in red shows Additions to Predicate device) INTENDED USE The devices in the Model 731 Ventilator Series are indicated for use in the management of infant through adult patients weighing ≥5 kg with acute or chronic respiratory failure or during resuscitation by providing continuous positive-pressure ventilation.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K111473, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 30, 2024Z-2130-2024Operator's Guide & Quick Reference Guide (QRG) ZOLL 731 Ventilator for MRI Compatible Devices. Patient Safety Ventilator MRI information omitted from the manuals. Update to the instructions ensures safe distance from…Open
Jun 30, 2017Z-0812-2018A software anomaly in the 731 software version 05/20/00, was identified, which can lead to a user inadvertently changing device settings.Terminated

Other CBK clearances

The newest 510(k)s for the same product code; their median review was 235 days; see every CBK device

Record

Type
Traditional
Received
May 27, 2011
Review panel
Anesthesiology
Regulation
21 CFR 868.5895

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.