Surgical Tissue Management System

Electrosurgical, Cutting & Coagulation & Accessories. 510(k) K111202, from Olympus Medical Systems Corp. (Center Valley, PA). Product code GEI, class 2.

As of Nov 19, 2026, K111202 is an FDA 510(k) held by Olympus Medical Systems Corp., substantially equivalent on Jan 20, 2012 after 266 days, with 10 recalls tied to it in FDA's recall database.

  • Review time: 266 days
  • Recalls: 10
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Surgical Tissue Management System The Surgical Tissue Management System is intended to be used with the Ultrasonic Generator (USG-400), the Electrosurgical Generator (ESG-400), the THUNDERBEAT Transducer (TD-TB400), the SONICBEAT Transducer (TD-SB400), the THUNDERBEAT, and / or the SONICBEAT for open, laparoscopic (including single-site surgery), and endoscopic surgery to cut (dissect) or…

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K111202, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Oct 22, 2025Z-1380-2026, Z-1378-2026, Z-1374-2026, Z-1382-2026, Z-1377-2026, Z-1376-2026, Z-1379-2026, Z-1381-2026, Z-1375-2026Firm is initiating a removal due to continued reports of adverse events.Open
Sep 27, 2013Z-0432-2014Complaints of damage to various models of Thunderbeat Hand Instruments during surgical procedures, including cracking, breaking, or deformation of the components of the probe tip or jaw.Terminated

Other GEI clearances

The newest 510(k)s for the same product code; their median review was 167 days; see every GEI device

Record

Type
Traditional
Received
Apr 29, 2011
Review panel
General, Plastic Surgery
Regulation
21 CFR 878.4400

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files