Newport HT70 Ventilator
Ventilator, Continuous, Facility Use. 510(k) K111146, from Newport Medical Instruments, Inc. (Costa Mesa, CA). Product code CBK, class 2.
As of Nov 19, 2026, K111146 is an FDA 510(k) held by Newport Medical Instruments, Inc., substantially equivalent on Dec 1, 2011 after 223 days, with 4 recalls tied to it in FDA's recall database.
- Review time: 223 days
- Recalls: 4
- Cited as a predicate by: 1 device
The Newport HT70 family of ventilators is intended to provide continuous or intermittent positive pressure mechanical ventilatory support for the care of individuals who require mechanical ventilation through invasive or non-invasive interfaces. Specifically, the Newport HT70 family of ventilators is applicable for infant, pediatric and adult patients greater than or equal to 5 kg (11 lbs).
- Newport HT70 Family of VentilatorsK090888 · Newport Medical Instruments, Inc. · Nov 18, 2009
- Ltv 1200 VentilatorK060647 · Pulmonetic Systems, Inc. · May 25, 2006
- Ivent 2001 Mri ConditionalK073694 · Versamed Medical Systems, Inc. · May 30, 2008
- Newport Aura VentilatorK121891 · Newport Medical Instruments, Inc. · Nov 9, 2012
| May 21, 2025 | Z-1915-2025Ventilator Printed Circuit Board Assembly may have two separate capacitors that may fail, which may result in the ventilator either shutting down during use, thus necessitating use of an alternate form of ventilation,… | Open |
| Mar 30, 2017 | Z-1874-2017Medtronic is issuing a voluntary field corrective action for all its Newport" HT70 and Newport" HT70 Plus ventilators because they may shutdown spontaneously during normal operation without an accompanying alarm. | Terminated |
| Apr 5, 2013 | Z-1171-2013Newport Medical Instruments is conducting a voluntary recall on certain Newport Medical Instruments HT70 and HT70 Plus ventilator Power Pac batteries due to customer reports of Newport HT70 and HT70 Plus ventilators… | Terminated |
| Aug 3, 2012 | Z-2250-2012May emit a continuous high priority alarm and the ventilator may stop ventilating, due to a component failure on the control board. | Terminated |
- Evita (V800); Evita (V600)K253647 · Draegerwerk AG & CO Kgaa · May 7, 2026
- Inbentus VersatileK252663 · Iconic Solutions by Murcia, SL · Apr 14, 2026
- VPAP Pediatric Face MaskK251888 · Hsiner Co., Ltd. · Mar 12, 2026
- Vivo 45 LSK232365 · Oconnell Regulatory Consultants, Inc. · Dec 19, 2025
- F&P OptiNIV Hospital Vented Full Face Mask Compatible with Single-limb Circuits – Size A (ONIV117A); F&P OptiNIV…K252173 · Fisher & Paykel Healthcare, Ltd. · Sep 10, 2025
- SV600, SV800 VentilatorK243767 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Aug 28, 2025
- AVEA disposable expiratory filter/water trap (11790)K251133 · Telesair, Inc. · May 8, 2025
- AF531 Oro-Nasal SE Face MaskK243394 · Respironics, Inc. · Dec 30, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 22, 2011
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5895
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files