Temporary Carotid Catheter For Embolic Capture. 510(k) K111010, from Ev3, Inc. (Plymouth, MN). Product code NTE, class 2.
As of Nov 19, 2026, K111010 is an FDA 510(k) held by Ev3, Inc., substantially equivalent on Oct 27, 2011 after 199 days, with no recalls tied to it in FDA's recall database.
- Review time: 199 days
- Recalls: 0
- Cited as a predicate by: 2 devices
The SpiderFX® Embolic Protection Device is indicated for use as a guidewire and embolic protection system to contain and remove embolic material in conjunction with the TurboHawk, either during standalone procedures or together with PTA and/or stenting, in the treatment of severely calcified lesions in arteries of the lower extremities.
- Spiderfx Embolic Protection DeviceK063204 · Ev3, Inc. · Nov 14, 2006
- Spiderx Embolic Protection DeviceK052659 · Ev3, Inc. · Feb 17, 2006
- Extra Pta Balloon Catheter With Embolic Protection FeatureK090364 · Angioslide, Ltd. · Mar 23, 2010
- Vanguard IEP Peripheral Balloon Angioplasty System with Integrated Embolic ProtectionK181529 · Contego Medical, LLC · Dec 6, 2018
- WirionK180023 · Gardia Medical , Ltd. · Mar 21, 2018
- Neuroguard IEP Embolic Protection SystemK260600 · Contego Medical, Inc. · Nov 4, 2026
- EmPro EPS (EP4514C-190, EP6514C-190);Nanoparasol EPS (PNP4514C-190,PNP6514C-190)K222694 · MicroVention, Inc. · Apr 27, 2023
- ENROUTE® Transcarotid Neuroprotection SystemK230402 · Silk Road Medical · Apr 11, 2023
- ANGIOGUARD XP Emboli Capture Guidewire, ANGIOGUARD RX Emboli Capture GuidewireK220654 · Cordis Corporation · Apr 6, 2022
- WIRION Embolic Protection SystemK210282 · Cardiovascular Systems, Inc. · Mar 3, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Apr 11, 2011
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1250
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files