Coren Total Hip System
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented. 510(k) K103431, from Corentec Co., Ltd. (San Diego, CA). Product code LPH, class 2.
As of Nov 17, 2026, K103431 is an FDA 510(k) held by Corentec Co., Ltd., substantially equivalent on Jul 21, 2011 after 240 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Jul 21, 2011
- Review time: 240 days
- Recalls: 0
- Cited as a predicate by: 4 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe COREN® Total Hip System is intended for use in total or partial hip arthroplasty and in primary or revision surgery for the following conditions: a. Non-inflammatory degenerative joint disease, such as avascular necrosis, osteoarthritis, traumatic arthritis b. Inflammatory degenerative joint disease, such as rheumatoid arthritis c.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Cls Spotorno StemK042249 · Zimmer Austin, Inc. · Sep 15, 2004
- Cls Varus Stem/Cls 135 StemK010839 · Sulzer Orthopedics, Inc. · Apr 18, 2001
- Excia Total Hip SystemK042344 · Aesculap, Inc. · Mar 16, 2005
- Lineage A-Class Poly LinerK052026 · Wrightmedicaltechnologyinc · Dec 5, 2005
Cited as a Predicate
4 later 510(k) summaries name this device as a predicate- Modified Bencox Hip SystemK150007 · Corentec Co., Ltd. · May 4, 2015
- Bencox Ii Stem, Bencox Metal HeadK122099 · Corentec Co., Ltd. · Oct 5, 2012
- Bencox Foret & Bencox DeltaK121665 · Corentec Co., Ltd. · Sep 25, 2012
- Bencox Mirabo Cup Bencox Mirabo Insert (Standard& Elevated Tyes) Bencox Mirabo Cup Screw…K120924 · Corentec Co., Ltd. · Sep 10, 2012
Other LPH Clearances
The newest 510(k)s for the same product code; their median review was 282 days; see every LPH device- G7® Acetabular SystemK261453 · Zimmer Biomet · Sep 23, 2026
- Mpact 3D Metal FoamK253630 · Medacta International S.A. · Aug 28, 2026
- TRIVANCE Hip StemK254043 · Globus Medical, Inc. · Aug 4, 2026
- Omnifit® 20° Series I Insert;Omnifit® Crossfire® 10° Series II Insert; Constrained…K261624 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · Jul 10, 2026
- iNSitu Lateralized Acetabular Liners, iNSitu Femoral Stems with Plasma Sprayed CPTi…K243192 · Nextstep Arthopedix, LLC · Jun 5, 2026
- Taperloc® Complete Hip StemK251270 · Biomet, Inc. · May 19, 2026
- G7® Revision Acetabular SystemK252623 · Zimmer, Inc. · Feb 4, 2026
- Mpact 3D Metal Implants Extension DMLS TechnologyK251043 · Medacta International S.A. · Jan 28, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 23, 2010
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3358
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files