Smith & Nephew Smf Hip Stem
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented. 510(k) K103256, from Smith & Nephew, Inc. (Memphis, TN). Product code LPH, class 2.
As of Nov 18, 2026, K103256 is an FDA 510(k) held by Smith & Nephew, Inc., substantially equivalent on Jan 31, 2011 after 89 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 89 days
- Recalls: 2
- Cited as a predicate by: 2 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFTotal hip components are indicated for uncemented use in individuals undergoing primary and revision surgery where other treatments or devices have failed in rehabilitating hips damaged as a result of trauma, inflammatory joint disease such as rheumatoid arthritis, or noninflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses such as osteoarthritis; avascular necrosis…
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Smith & Nephew Mis Hip Stem With StiktiteK080625 · Smith & Nephew, Inc. · May 8, 2008
- Anthology Hip StemK052792 · Smith & Nephew, Inc. · Oct 7, 2005
Cited as a predicate
2 later 510(k) summaries name this device as a predicate- Ovation Tribute Hip Stem; Ovation Narrow Hip StemK133386 · Ortho Development Corp. · Mar 11, 2014
- Smith & Nephew Smf Hip StemK123012 · Smith & Nephew, Inc. · Oct 24, 2012
Recalls
Recalls FDA ties to K103256, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| Started | Recall | Status |
|---|---|---|
| Feb 19, 2019 | Z-1028-2019, Z-1029-2019Complaints were received indicating that the outer label incorrectly identified the product as size "1" instead of "-1". The product contained within the package is size "-1" | Terminated |
Other LPH clearances
The newest 510(k)s for the same product code; their median review was 282 days; see every LPH device- G7® Acetabular SystemK261453 · Zimmer Biomet · Sep 23, 2026
- Mpact 3D Metal FoamK253630 · Medacta International S.A. · Aug 28, 2026
- TRIVANCE™ Hip StemK254043 · Globus Medical, Inc. · Aug 4, 2026
- Omnifit® 20° Series I Insert;Omnifit® Crossfire® 10° Series II Insert; Constrained Acetabular Insert; Trident®…K261624 · Howmedica Osteonics Corp., Dba Stryker Orthopaedics · Jul 10, 2026
- iNSitu Lateralized Acetabular Liners, iNSitu Femoral Stems with Plasma Sprayed CPTi CoatingK243192 · Nextstep Arthopedix, LLC · Jun 5, 2026
- Taperloc® Complete Hip StemK251270 · Biomet, Inc. · May 19, 2026
- G7® Revision Acetabular SystemK252623 · Zimmer, Inc. · Feb 4, 2026
- Mpact 3D Metal Implants Extension – DMLS TechnologyK251043 · Medacta International S.A. · Jan 28, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Abbreviated
- Received
- Nov 3, 2010
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3358
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files