Blood Sampling Set
Set, Administration, Intravascular. 510(k) K103165, from Acacia, Inc. (Brea, CA). Product code FPA, class 2.
As of Nov 20, 2026, K103165 is an FDA 510(k) held by Acacia, Inc., substantially equivalent on Nov 10, 2010 after 14 days, with no recalls tied to it in FDA's recall database.
- Review time: 14 days
- Recalls: 0
The Blood Sampling Set is indicated for fluid flow directional control and for providing access port(s) for administration of solutions. Typical uses include pressure monitoring, intravenous fluid administration and transfusion.
- Closed Swabable Stopcock and Minimal Residual Volume Luer-Activated Swabable-StopcockK060231 · Elcam Medical Acal · Apr 13, 2006
- Intravenous Extension SetK895367 · Medical Product Specialists · Oct 6, 1989
- Gravity Blood Sets with 200µm FilterK260261 · B.Braun Medical, Inc. · Oct 22, 2026
- Ecomed Disposable Administration SetsK254123 · Ecomed Solutions, LLC · Sep 11, 2026
- iiSure Infusion SetK261530 · Deka Research and Development · Jun 3, 2026
- AMSafe Administration Set (BA-70075, BA-70071-D, BA-70070, BA-70071-P, BA-70072, BA-70072-F, BA-70071-DF,…K252543 · Amsino International, Inc. · May 4, 2026
- PuraCath Firefly Needleless Connector IT (9005)K251375 · Puracath Medical, Inc. · Feb 12, 2026
- nSet+ Stabilization Set [6426733]; nSet+ Stabilization Set with nSyte Needle Free Connector (NFC) [6426731]; nSyte…K251257 · Np Medical · Dec 4, 2025
- BD Alaris Pump Infusion SetK250325 · Carefusion (Bd) · Oct 30, 2025
- EZ™ IV Administration SetK251814 · Epic Medical Pte. , Ltd. · Aug 29, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Oct 27, 2010
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5440
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files