Arca
Skip to content
Tools
Tools

Resolution Ii Clip

Hemostatic Metal Clip For The Gi Tract. 510(k) K102764, from Boston Scientific Corporation (Marlboro, MA). Product code PKL, class 2.

As of Nov 26, 2026, K102764 is an FDA 510(k) held by Boston Scientific Corporation, substantially equivalent on Dec 22, 2010 after 89 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 89 days
  • Recalls: 1

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

K102764 510(k) Number (if known): To Be Determined DEC 2 2 2010 Device Name: Resolution II Clip The Resolution II Clip is indicated for clip placement within the Gastrointestinal Tract for the purpose of: 1. Endoscopic Marking 2. Hemostasis for: • Mucosal/sub-mucosal defects < 3 cm - Bleeding ulcers - Arteries < 2 mm - Polyps < 1.5 cm in diameter • Diverticula in the colon 3.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K102764, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Jul 19, 2011Z-3056-2011Boston Scientific has received reports where, following clip deployment, the alignment of the clip and delivery system does not allow for the withdrawal of the delivery system away from the clip, resulting in tissue…Terminated

Other PKL clearances

The newest 510(k)s for the same product code; their median review was 231 days; see every PKL device

Record

Type
Traditional
Received
Sep 24, 2010
Review panel
Gastroenterology, Urology
Regulation
21 CFR 876.4400

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files