Ventilator, Continuous, Non-Life-Supporting. 510(k) K102465, from Respironics, Inc. (Murrysville, PA). Product code MNS, class 2.
As of Nov 19, 2026, K102465 is an FDA 510(k) held by Respironics, Inc., substantially equivalent on Mar 24, 2011 after 209 days, with 1 recall tied to it in FDA's recall database.
- Review time: 209 days
- Recalls: 1
- Cited as a predicate by: 2 devices
Indications for Use 510(k) Number (if known): ____ Device Name: BiPAP AVAPS with Oximetry Module The Nonin Xpod Oximetry Module can be used with Philips Respironics BiPAP C Series therapy devices (BiPAP AVAPS and BiPAP S/T) to measure functional oxygen saturation of arterial hemoglobin (%SpO2) and pulse rate for adult and pediatric patients.
- Bipap Avaps Ventilatory Support SystemK092818 · Respironics, Inc. · Jan 22, 2010
- Devilbiss DV5M Smartlink SystemK082209 · Sunrise Medical · Oct 28, 2008
- S7 Elite and Autoset Spirit Cpap Systems With ReslinkK024191 · Resmed, Ltd. · Jul 2, 2003
- F&P myAirvo 3K222292 · Fisher & Paykel Healthcare · May 8, 2024
- Oximetry Interface KitK111378 · Philips Respironics, Inc. · Oct 4, 2011
| Started | Recall | Status |
|---|---|---|
| Jun 14, 2021 | Z-1973-2021The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the device s the air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. | Open |
- myAirK251889 · Resmed Corp · Apr 8, 2026
- BreathePal Bilevel (GFM50-MD2201)K252078 · Compal Electronics, Inc. · Mar 17, 2026
- Mariana Minerva; Mariana NimbusK251661 · Resmed Pty , Ltd. · Feb 23, 2026
- Vivo 1, Vivo 2K240778 · Breas Medical AB · Dec 13, 2024
- ReddyPort ElbowK231064 · Smd Manufacturing, LLC · Jul 13, 2023
- BPAP SystemK213169 · BMC Medical Co., Ltd. · Dec 5, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 27, 2010
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5895
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files