Moorvms-Pres Pressure Cuff Controller
Flowmeter, Blood, Cardiovascular. 510(k) K102433, from Moor Instruments, Ltd. (Axminster, Devon, GB). Product code DPW, class 2.
As of Nov 19, 2026, K102433 is an FDA 510(k) held by Moor Instruments, Ltd., substantially equivalent on Nov 18, 2010 after 84 days, with no recalls tied to it in FDA's recall database.
- Review time: 84 days
- Recalls: 0
The moorVMS-PRES pressure cuff controller is a device for cuff inflation and deflation control and pressure measurement. It is intended to allow non-invasive measurement of skin perfusion pressure, pulse volume, systolic blood pressure and ankle/toe brachial pressure index when used with a laser Doppler monitor either manually by the operator or automatically by separate dedicated PC software.
- PF 5050 Pressure Unit, Model PF 5050K011899 · Perimed AB · Nov 6, 2001
- FlowXL® System: FlowXL Flowmeter and compatible Flowprobes and FlowsensorsK261714 · Transonic Systems, Inc. · Oct 27, 2026
- BlueDop Vascular ExpertK260700 · BlueDop Medical, Ltd. · Jul 8, 2026
- FloPatch FP120K252810 · Flosonics Medical · Apr 24, 2026
- VascuChek Kit, VascuChek Transceiver, VascuChek Clinical Probe, VascuChek Speaker Dock (VC-KIT-02, VC-TRX-02, VC-CP-01,…K251904 · Remington Medical, Inc. · Nov 20, 2025
- FloPatch FP120K251114 · Flosonics Medical · Jun 20, 2025
- Elfor-LK243852 · Elfi-Tech , Ltd. · Apr 14, 2025
- VascuChek Kit, VascuChek Transceiver, VascuChek Clinical Probe, VascuChek Charger (VC-KIT-01, VC-TRX-01, VC-CP-01,…K241583 · Remington Medical, Inc. · Aug 30, 2024
- FloPatch FP120K223843 · Flosonics Medical · May 3, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 26, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2100
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files