Obs Disposable Electrosurgical Pads, Monopolar, Biopolar, Models Gbs-Dm, Gbs-Db

Electrosurgical, Cutting & Coagulation & Accessories. 510(k) K102372, from Jiangmen City Xinhui Baisheng Medical Equipment CO (Jiangmen City, Guangdong, CN). Product code GEI, class 2.

As of Nov 20, 2026, K102372 is an FDA 510(k) held by Jiangmen City Xinhui Baisheng Medical Equipment CO, substantially equivalent on Nov 3, 2010 after 75 days, with no recalls tied to it in FDA's recall database.

  • Review time: 75 days
  • Recalls: 0
  • Cited as a predicate by: 4 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

OBS Disposable Electrosurgical Pads are Neutral Electrode which is also known as plate, plate electrode, passive, return, or dispersive electrode. They are indicated for use to adhere to the patient over the entire pad surface to complete an electrical circuit during electrosurgery between the electrosurgical generator, the active electrode and the patient.

Cited as a predicate

4 later 510(k) summaries name this device as a predicate
  • AgnesK223805 · Agnes Medical Co., Ltd. · May 4, 2023
  • AgnesK203013 · Agnes Medical Co., Ltd. · Jul 14, 2022
  • AgnesK192728 · Agnes Medical Co., Ltd. · Oct 24, 2019
  • Disposable Neutral Electrode GP202K130027 · Cathay Manufacturing Corp. · Aug 22, 2013

Other GEI clearances

The newest 510(k)s for the same product code; their median review was 167 days; see every GEI device

Record

Type
Traditional, third-party review
Received
Aug 20, 2010
Review panel
General, Plastic Surgery
Regulation
21 CFR 878.4400

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files