Radiological Image Processing System
System, Image Processing, Radiological. 510(k) K102078, from VATECH Co., Ltd. (Secaucus, NJ). Product code LLZ, class 2.
As of Nov 17, 2026, K102078 is an FDA 510(k) held by VATECH Co., Ltd., substantially equivalent on Aug 10, 2011 after 380 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Aug 10, 2011
- Review time: 380 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFXmaruView V1 software is to make the processing and administration of medical X-ray images as efficient as possible. Functions to be carried out using XmaruView V1 is, for example, but not limited to, adjustment of window leveling, rotation, zoom, and measurements. XmaruView V1 software can control X-ray generator acquisition settings.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Dicompacs, Model 5.2, Dicompacs Dx-R, Model 1.4K091364 · Oehm Und Rehbein GmbH · Dec 11, 2009
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Xmaru View V1 and Xmaru PACS, Medical Image Processing SoftwareK160579 · Rayence Co., Ltd. · Apr 8, 2016
Other LLZ Clearances
The newest 510(k)s for the same product code; their median review was 110 days; see every LLZ device- Vitrea Advanced Visualization, Version 7.16K263648 · Canon Medical Informatics, Inc. · Oct 29, 2026
- MIM KineticIDK261763 · Mim Software, Inc. · Oct 26, 2026
- PV-iCurve ProK261531 · Perception Vision Medical Technology Co., Ltd. · Oct 21, 2026
- Eden PACSK261788 · Higia., Inc. d/b/a Eden · Oct 21, 2026
- Syngo Carbon Space (VA4)K263048 · Siemens Healthineers AG · Sep 29, 2026
- Syneris PACS v.1.0.1.0K261874 · Syneris · Sep 23, 2026
- HipStudio AnalysisK262442 · Replasia BV · Sep 22, 2026
- Elucid PlaqueIQK261855 · Elucid Bioimaging, Inc. · Sep 18, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 26, 2010
- Review panel
- Radiology
- Regulation
- 21 CFR 892.2050
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files