Patch, Pledget And Intracardiac, Petp, Ptfe, Polypropylene. 510(k) K101866, from Cryolife, Inc. (Kennesaw, GA). Product code DXZ, class 2.

As of Nov 22, 2026, K101866 is an FDA 510(k) held by Cryolife, Inc., substantially equivalent on Jul 23, 2010 after 21 days, with 5 recalls tied to it in FDA's recall database.

  • Review time: 21 days
  • Recalls: 5

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

CryoPatch SG Pulmonary Human Cardiac Patch is indicated for repair or reconstruction of the right ventricular outflow tract

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K101866, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Sep 18, 2026Z-0325-2027A cryopreserved pulmonary human cardiac patch, taken from a 64-year-old human donor, was outside the cardiac tissue donor age specification of newborn to 60 years. The patch was implanted, and due to limitations of…Open
Nov 10, 2020Z-0653-2021On November 10, 2020, it was discovered that there are post- processing microbial culture test failures for other allografts, processed using a TRIS saline solution lot that was also used in processing allografts…Terminated
May 14, 2018Z-2272-2018Devices, which met FDA and AATB eligibility criteria, were distributed. Final autopsy and toxicology reports indicated the presence of morphine in the urine.Terminated
Nov 22, 2013Z-0809-2014Serological testing for the donor was performed with a blood sample that may have been hemodiluted due to the administration of normal saline to the donor prior to death.Terminated
Feb 17, 2011Z-1561-2011Staphylococcus aureus (not methicillin resistant) identified in companion tissue.Terminated

Other DXZ clearances

The newest 510(k)s for the same product code; see every DXZ device

Record

Type
Special
Received
Jul 2, 2010
Review panel
Cardiovascular
Regulation
21 CFR 870.3470

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.