Modification To: CG-6108 ACT-3L Continuous Ecg Monitor and Arrhythmia Detector, Model FG-00084
Detector And Alarm, Arrhythmia. 510(k) K101703, from Card Guard Scientific Survival , Ltd. (Lakewood, CO). Product code DSI, class 2.
As of Nov 23, 2026, K101703 is an FDA 510(k) held by Card Guard Scientific Survival , Ltd., substantially equivalent on Jul 13, 2010 after 26 days, with no recalls tied to it in FDA's recall database.
- Review time: 26 days
- Recalls: 0
- Cited as a predicate by: 1 device
The CG-6108 ACT-3L Continuous ECG Monitor and Arrhythmia Detector is intended for use by patients who experience transient symptoms that may suggest cardiac arrhythmia. The device continuously monitors patient ECG, automatically generates an alarm triggered by an arrhythmia detection algorithm, or generates an alarm manually triggered by the patient, and transmits the recorded data…
- CG-6108 ACT-3L Continuous Ecg Monitor & Arrhythmia DetectorK081257 · Card Guard Scientific Survival , Ltd. · May 29, 2008
- CG-5108 ACT-3L Continuous Ecg Monitor and Arrhythmia DetectorK110499 · Card Guard Scientific Survival , Ltd. · Apr 6, 2011
- BodyGuardian Remote Monitoring System (BGRMS v3.0)K243349 · Boston Scientific Cardiac Diagnostic Technologies, Inc. · Jan 23, 2026
- MoMe ARC® Wireless Ambulatory ECG Monitoring and Detection System (32000)K250356 · Infobionic, Inc. · Jul 29, 2025
- Zio AT® device (A100A1001)K240177 · iRhythm Technologies, Inc. · Oct 30, 2024
- MoMe® ARC Wireless Ambulatory ECG Monitoring and Detection SystemK230265 · Infobionic, Inc. · Oct 6, 2023
- SmartCardia 7L PlatformK231276 · Smartcardia SA · Aug 30, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 17, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1025
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files