CG-6108 Act-Il Continuous Ecg Monitor and Arrythmia Detector
Detector And Alarm, Arrhythmia. 510(k) K101639, from Card Guard Scientific Survival , Ltd. (Lakewood, CO). Product code DSI, class 2.
As of Nov 21, 2026, K101639 is an FDA 510(k) held by Card Guard Scientific Survival , Ltd., substantially equivalent on Jun 25, 2010 after 15 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 15 days
- Recalls: 2
- Cited as a predicate by: 2 devices
The CG-6108 Continuous ECG Monitor and Arrhythmia Detector is intended for use by patients who experience transient symptoms that may suggest cardiac arrhythmia. The device continuously monitors a one lead ECG, automatically generates an alarm triggered by an arrhythmia detection algorithm or generates an alarm manually triggered by the patient, and transmits the recorded data transtelephonically…
- CG-6108 Continuous Ecg Monitor and Arrhythmia DetectorK071995 · Card Guard Scientific Survival , Ltd. · Dec 18, 2007
- ECG Mini System Continuous ECG Monitor and Arrhythmia DetectorK151269 · Lifewatch Technologies , Ltd. · Jan 15, 2016
- King of Hearts Express Af Cardiac Event RecorderK111745 · Card Guard Scientific Survival , Ltd. · Aug 1, 2011
| Started | Recall | Status |
|---|---|---|
| Sep 26, 2011 | Z-0206-2012, Z-0208-2012LifeWatch received complaints of minor shocks and burns during use of the LifeStar ACT systems with shorts in the leads. | Terminated |
- BodyGuardian Remote Monitoring System (BGRMS v3.0)K243349 · Boston Scientific Cardiac Diagnostic Technologies, Inc. · Jan 23, 2026
- MoMe ARC® Wireless Ambulatory ECG Monitoring and Detection System (32000)K250356 · Infobionic, Inc. · Jul 29, 2025
- Zio AT® device (A100A1001)K240177 · iRhythm Technologies, Inc. · Oct 30, 2024
- MoMe® ARC Wireless Ambulatory ECG Monitoring and Detection SystemK230265 · Infobionic, Inc. · Oct 6, 2023
- SmartCardia 7L PlatformK231276 · Smartcardia SA · Aug 30, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Jun 10, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1025
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files