Rvt Cto Device
Catheter For Crossing Total Occlusions. 510(k) K101599, from Revascular Therapeutics, Inc. (Sunnyvale, CA). Product code PDU, class 2.
As of Nov 21, 2026, K101599 is an FDA 510(k) held by Revascular Therapeutics, Inc., substantially equivalent on Jan 18, 2011 after 225 days, with no recalls tied to it in FDA's recall database.
- Review time: 225 days
- Recalls: 0
- Cited as a predicate by: 1 device
The RVT CTO Device is indicated to facilitate the intra-luminal placement of conventional guidewires beyond peripheral artery chronic total occlusions. The device is contraindicated for use in carotid arteries. The RVT Extension Wire is designed to extend the RVT CTO Device so that a catheter can be exchanged for another catheter.
- The Crosser SystemK072776 · Flowcardia, Inc. · Dec 7, 2007
- Modification To The Crosser SystemK091119 · Flowcardia, Inc. · May 15, 2009
- RF Tunneler WireK051670 · Baylis Medical Co., Inc. · Mar 30, 2006
- Truepath Cto DeviceK140288 · Boston Scientific Corp · Apr 16, 2014
- Kiba CTO Crossing CatheterK262013 · Reflow Medical, Inc. · Aug 28, 2026
- Santreva™-ATK Endovascular Revasculariztion CatheterK252315 · AngioSafe, Inc. · Sep 22, 2025
- LimFlow ARCK251376 · LimFlow, Inc. · May 31, 2025
- SoundBite® Crossing System XS PeripheralK230159 · Soundbite Medical Solutions, Inc. · Aug 28, 2023
- Tigereye ST CTO-Crossing CatheterK230594 · Avinger, Inc. · Apr 25, 2023
- Tunnel Crossing CatheterK221163 · Tractus Vascular, LLC · Jan 19, 2023
- LimFlow ARCK221541 · LimFlow, Inc. · Aug 31, 2022
- DABRA Excimer Laser System (DABRA Laser model RA-308 and DABRA Catheter model 2.0)K220544 · Ra Medical Systems,Inc · Jun 29, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 7, 2010
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1250
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files